L oad C ell S ensors Starrett offers a full range of accessories including sensor technologies for precision load and strain measurements. These sensors interface seamlessly with our testing frames and are “self-recognizing”. Starrett sensors are ideal for demanding material testing and force measurement applications. All load cell sensors are compliant with IEEE 1451.4 and meet or exceed ASTM E4, BS 1610, ISO 7500-1 and EN 10002-2. Sensors are supplied with a NIST-traceable Certificate of Calibration. Load accuracy on all sensors is 0.1% full scale.
MLC Series - Material Test Low-profile Sensors Model Number Load Capacity
Safe Overload Full Scale Deflection Height 1
Width
Thread
N KGF LBF % Full Scale in
mm in
mm in mm mm
MLC-125 125 12.5 28
150 150
0.003 0.08 0.003 0.08 0.003 0.08 0.003 0.08 0.001 0.03 0.001 0.03 0.001 0.03 0.001 0.03 0.002 0.05 0.002 0.05
1.5 38.1 2.75 69.8 M6 x 1-6H 1.5 38.1 2.75 69.8 M6 x 1-6H 1.5 38.1 2.75 69.8 M6 x 1-6H 1.5 38.1 2.75 69.8 M6 x 1-6H 2.51 104.8 4.13 104.8 M16 x 2-4H 2.51 104.8 4.13 104.8 M16 x 2-4H 2.51 104.8 4.13 104.8 M16 x 2-4H 2.51 104.8 4.13 104.8 M16 x 2-4H 2.51 104.8 4.13 104.8 M16 x 2-4H 2.51 104.8 4.13 104.8 M16 x 2-4H
MLC-250 250 25 MLC-500 500 50
56
112 150
MLC-1000 1000 100 225 150 MLC-1500 1500 150 337 150 MLC-2500 2500 250 562 150
MLC-5K
5000 500 1124 150
MLC-10K 10,000 1000 2248 150 MLC-25K 25,000 2500 5620 150 MLC-50K 50,000 5000 11,240 150
NOTES MLC Sensors cannot be used with FMM Test Frames or with S1 systems. Load measurement accuracy is ±0.05% of load cell capacity. Display resolution is 10,000:1. Height includes the base adapter
FLC-P Series - Force Measurement Premium Sensors
Load Capacity
Safe Overload Full Scale Deflection Height
Width
Thread
Model Number
N KGF LBF % Full Scale in
mm in
mm in
mm mm
FLC-5P FLC-10P FLC-25P FLC-50P FLC-100P FLC-250P
5
0.5 1
1000 1000 1000
0.014 0.4 0.012 0.3 0.011 0.3 0.009 0.2 0.007 0.2 0.006 0.2
2.48 63.0 2.33 59.2 M6 x 1-6H 2.48 63.0 2.33 59.2 M6 x 1-6H 2.48 63.0 2.33 59.2 M6 x 1-6H 2.48 63.0 2.33 59.2 M6 x 1-6H 2.48 63.0 2.33 59.2 M6 x 1-6H 2.48 63.0 2.33 59.2 M6 x 1-6H
10 1
2
25 2.5 5
50 5
11 1000
100 10 22 1000 250 25 56 1000
NOTES FLC-P Sensors cannot be used with FMM Test Frames or with S1 systems. Load measurement accuracy is ±0.1% of load cell capacity. Display resolution is 10,000:1.
FLC-E Series - Force Measurement Economy Sensors
Load Capacity
Safe Overload Full Scale Deflection Height
Width
Thread
Model Number
N KGF LBF % Full Scale in
mm in mm in
mm mm
FLC-50E FLC-100E FLC-200E FLC-500E
50 5
11 150
0.003 0.08 0.003 0.08 0.003 0.08 0.004 0.10 0.006 0.15 0.006 0.15 0.005 0.13 0.005 0.13
2.5 63.5 2.0 50.8 M6 x 1-6H 2.5 63.5 2.0 50.8 M6 x 1-6H 2.5 63.5 2.0 50.8 M6 x 1-6H 2.5 63.5 2.0 50.8 M6 x 1-6H 2.5 63.5 2.0 50.8 M6 x 1-6H 3.0 76.2 2.0 50.8 M6 x 1-6H 3.0 76.2 2.0 50.8 M6 x 1-6H 3.0 76.2 2.0 50.8 M6 x 1-6H
100 10 22 150 200 20 45 150 500 50 112 150
FLC-1000E 1000 100 225 150 FLC-2000E 2000 200 450 150 FLC-2500E 2500 250 562 150 FLC-5000E 5000 500 1124 150
NOTES FLC-E Sensors cannot be used with FMM Test Frames or with S1 systems. Load measurement accuracy is ±0.1% of load cell capacity. Display resolution is 10,000:1.
BLC Series - Basic Force Measurement S-beam Sensors (Use with FMM Test Frames and S1 Software only)
Load Capacity
Safe Overload Full Scale Deflection Height
Width
Thread
Model Number
N KGF LBF % Full Scale in
mm in mm in mm mm
BLC-2 BLC-5
10 1 20 2 50 5
2 5
150 150
0.009 0.22 0.008 0.21 0.007 0.18 0.007 0.18 0.006 0.15 0.003 0.08 0.003 0.08 0.005 0.13
3.0 76.2 3.0 76.2 M6 x 1-6H 3.0 76.2 3.0 76.2 M6 x 1-6H 3.0 76.2 3.0 76.2 M6 x 1-6H 2.0 50.8 2.0 50.8 M6 x 1-6H 2.0 50.8 2.0 50.8 M6 x 1-6H 2.0 50.8 2.0 50.8 M6 x 1-6H 2.0 50.8 2.0 50.8 M6 x 1-6H 2.0 50.8 2.0 50.8 M12 x 1.75-5H
BLC-10 BLC-20 BLC-50 BLC-100 BLC-200 BLC-500
10 150
100 10 20 150 250 25 50 150 500 50 110 150 1000 100 225 150 2500 250 550 150
NOTES BLC Sensors are to be used on FMM test frames and S1 systems. They may not be used with MMS, FMS, MMD or FMD test frames or with S2, L2Plus or L3 software. Load measurement accuracy is ±0.1% of load cell capacity. Display resolution is 10,000:1. Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.
16