T est S etup O ptions • Pre-Test Options - Units of Measurement
- User Prompts to assist operator during testing - Spring preconditioning (Scrag & Load Set Hold for duration)
• Test Options
- Measure Free Length - One Point Limit Test (Load or Height)
- Two Point Limit Test (Load and/or Height) - Exceptions (Abort test if an exception is met)
• Data Options
- Spring Constant (One Point) - Spring Rate (Two Point) - Date, User, Limit Setpoints
• Post-Test Options
- Export Raw Data to a file location (up to 1000 pts/second) - Export Results (Overwrite or Append data file)
Your two-point test setups may be based on a load or height target. (Top) Height targets are used as setpoints where the KSR is determined based on the spring length. (Bottom) Load targets are used as setpoints to determine KSR. The “Stop Test If” conditions will stop a test should either the Max Load or Max Height be encountered. SI units of measure are being used.
With the S2 software you can overlay the graphs of multiple test results to verify each spring against a benchmark curve. Imperial units are used.