Charcon brochure

INSTALLATION GUIDE

SYSTEM DRAINAGE AREAS: GRADIENT AGAINST RAINFALL INTENSITY BY NOMINAL BORE

Gradient

Rainfall intensity (discharge l/s)

Area drained 30mm/hr

Area drained 40mm/hr

Area drained 50mm/hr

Area drained 75mm/hr

Nominal bore (mm)

125

125

125

125

125

1:50 (2.00%)

15.1

1860

1400

1120

740

1:100 (1.00%)

10.9

1310

980

790

520

1:200 (0.50%)

7.7

920

690

550

370

1:300 (0.33%)

6.2

750

560

450

300

1:400 (0.25%)

5.4

650

480

390

260

1:500 (0.20%)

4.8

580

430

350

230

1:1000 (0.10%)

3.3

400

300

240

100

Class A 15kN

Class B 125kN

Class C 250kN

Class D 400kN

Class E 600kN

Class F 900kN

Unit weight (kg)

Unit/bore (mm)

Main units DBA/125

102

DBM/125

106

DBG/DI/125

107

DBK HB2/125

129

Accessories Type A silt box top

115

Type H silt box top

148

Inspection unit DBG/DI/125

107

Inspection unit kerb HB2/125

129

Manhole cover kerb HB2/125

175

Transition kerb HB2/125

109

• indicates suitability Key to unit abbreviations: HB half batter, DI ductile iron BS EN 1433 standard classifications Class A (15kN): Pedestrian areas, walkways and cycle tracks. Class B (125kN): Pedestrianised areas and car parks with limited vehicle access. Class C (250kN): Kerbside drainage to public highways, parking areas, service stations and pedestrian areas.

Class D (400kN): Public highways and general parking areas. (Note: Grid systems should not be used for fast moving traffic.) Class E (600kN): Heavy industrial sites, dockyards and lorry parks. Class F (900kN): Airport taxiways and specialist industrial sites.

145

TECHNICAL INFORMATION: charcon.technical@aggregate.com

Made with FlippingBook - professional solution for displaying marketing and sales documents online