Installation clamping module

Hydraulic opening. Pneumatic blow-out. Opening operating pressure: min. 50 bar - max. 60 bar. Installation clamping module

Model Size Pull-in/locking force up to [kN]

Holding force [kN]

Blow out Weight [Kg]

10 20 40

25 55

● ● ●

0.45 1.40 3.40

570253 KH10 570254 KH20 570255 KH40

105

Cover and piston hardened. Repeatability < 0.005 mm.

Application: Zero-point clamping system for set-up-time-optimised clamping during cutting and non-cutting machining. Note: The installation clamping module has high holding, pull-in and locking forces. This is opened hydraulically (1) and mechanically locked through spring force. Subsequent uncoupling of the pressure lines is possible at all times (module is tensioned pressure- free). The clamping module with blow-out and support control has two connections: 1x hydr. opening (1) / 1x pneum. blow-out and support control (3). (The pneumatic blow-out and support control can optionally be connected.) Dimensions: Model Size dia.D [mm] dia.DN [mm] dia.D1 [mm] H [mm] HA [mm] dia.LK [mm] M T [mm] 570253 KH10 78 22 50 30 7 60 M523 570254 KH20 112 32 78 44 10 88 M6 34 570255 KH40 148 40 102 57 15 118 M8 42

Pneumatic opening. Pneumatic blow-out. Opening operating pressure: min. 8 bar - max. 12 bar. Retensioning operating pressure (turbo): min. 5 bar - max. 6 bar. Installation clamping module

Model Size Pull-in/locking force up to [kN]

Holding force [kN]

Blow out Weight [Kg]

8

25 55

● ●

0,45 1,40

570256 KP10 570257 KP20

17

Application: Zero-point clamping system for set-up-time-optimised clamping during cutting and non-cutting machining. Note: The installation clamping module has high holding, pull-in and locking forces. This is opened pneumatically (1) and locked mechanically through spring force. To achieve the specified pull-in and locking forces, it must be briefly retensioned pneumatically (turbo) (2). Subsequent uncoupling of the pressure lines is possible at any time (module is clamped pressure-free). The clamping module with blow-out and support control has three connections: 1x pneum. Opening (1) / 1x pneum. Retensioning (turbo) (2), 1x pneum. Blow-out and support control (3). (The pneumatic blow-out and support control can optionally be connected.) Dimensions: Model Size dia.D [mm] dia. DN [mm] dia. D1 [mm] H [mm] HA [mm] dia. LK [mm] M T [mm] 570256 KP10 78 22 50 30 7 60 M523 570257 KP20 112 32 78 44 10 88 M6 34

Cover and piston hardened. Repeatability < 0.005 mm.

8 ZERO-POINT-SYSTEMS 

Phone: 800-992-0236 ∙ Web: www.vektek.com

Made with FlippingBook - Online Brochure Maker