GSK Product Pack Jun2023

Partition SM60 Metal coatings and mineral wool core

GSP-0203-E/C

Technical characteristics

Vertical panel

Thickness

60 mm 2.36’’

0,20 m 0.65’ ; 0,25 m 0.82’ ; 0,35 m 1.15’ ; 0,55 m 1.80’ ; 0,80 m 2.62’ ; 1,00 m 3.28

Widths

1,20 m 3.94’

Maxi. lengths

4 m 13.12’

6 m 19.68’

Thermal conductivity coefficient

λ = 0,041 W/m.°C 0.023 Btu.ft/h.ft².°F

Thermal transmission coefficient

Uc = 0,612 W/m 2 .°C 0.109 Btu/h.ft².°F

R-value

1,6

Acceptable resisting to buckling

≥ 210 kPa 30.46 PSI (2,1 daN/cm 2 30.45 lbf/sp.in )

Weight

17 kg/m 2 3.48 lbs/sq.ft (2 faces 0,6 mm 0.02’’ )

Tightness in whole partition with silicon joint

Qs ≤ 0,0027 m 3 /h.m 2 0.0088 ft3/h.ft² under ∆P = 50 Pa 0.007 PSI

Maximum acceptable loads in partition

Bending resistance, panels on 2 supports

Partition height (m)

2,50 8.20’

3,00 9.84’

3,50 11.48’

4,00 13.12’

≥ 4,50 14.76’

q (daN/m 2 )

75 15.67 lbf/ft²

55 11.49 lbf/ft²

42 8.78 lbf/ft²

30 6.27 lbf/ft²

20 4.18 lbf/ft²

Installation

Profiles integrated in the thickness of SM panels, allow the assembly of panels and the passage of cables. The system uses an aluminium key profile that is inserted into the full length grooves both sides of wall panels. A special feature without the link profile allows this partition to become removable panel by panel, thanks to stainless steel clips. Assembly

joint silicone

profile

stainless steel clips

Assembly between panels

Tightness - Silicon sealant (quality-label SNJF ; complies with FDA 21 CFR 175.105) - Polymer MS caulk

09-07-2019

Non contractual document - Dagard reserves the right to modify its products without notice.

02-03-2

DAGARD - Route du Stade - 23600 Boussac - FRANCE

info@dagard.com - www.dagard.com