Ariston Electric Water Heaters

500- 12

500- 24

750- 12

750- 24

750- 36

1000- 12

1000- 24

1000- 36

1500- 12

1500- 24

PERFORMANCE DATA

Power

kW

12

24

12

24

36

12

24

36

12

24

Panel*** Voltage

SB-SF

SB-SF

SB-SF

SB-SF

SB-SF

SB-SF

SB-SF

SB-SF

SB-SF

SB-SF

V

400

400

400

400

400

400

400

400

400

400

Heating Elements

1

2

1

2

3

2

2

3

2

2

Recovery time DT 40°C rise Recovery time DT 45°C rise

min. min.

116 131

58 65

174 196 258 229 783 754

87 98

58 65

233 262 258 229 958 929

116 131

78 87

349 392 258 229 1308 1279

174 196 516 459

Flow rate 40°C rise Flow rate 45°C rise

l l l l

258 229 608 579

516 459 866 809

516 459 1041 984

774 688 1299 1213

516 459 1216 1159

774 688 1474 1388

First hour delivery 40°C rise First hour delivery 45°C rise

1566 1509

*** SB = Basic panel - SF = Full panel

CODE

With soft jacket - Basic panel With soft jacket - Full panel

3080029 3080081 3080260 3080273 3080274 3080333 3080334 3080335 3080336 3080337

3104098 3104099 3104101

3104102 3104103 3104104 3104105 3104106 3104107 3104108

1500- 36

2020- 24

2020- 36

2020- 48

2500- 36

2500- 48

2500- 60

3000- 48

3000- 60

3000- 80

PERFORMANCE DATA

Power

kW

36

24 SF

36 SF

48 SF

36 SF

48 SF

60 SF

48 SF

60 SF

80 SF

Panel*** Voltage

SB-SF

V

400

400

400

400

400

400

400

400

400

400

Heating Elements

3

2

3

4

3

4

3

4

5

5

Recovery time DT 40°C rise Recovery time DT 45°C rise

min. min.

116 131

233 262 516 459 1916 1859

155 174 774 688 2174

116 131

194 218 774 688

145 164

116 131

174 196

140 157

105

118

Flow rate 40°C rise Flow rate 45°C rise

l l l l

774 688 1824 1738

1032

1032

1290

1032

1290

1720 1529

917

1147

1147

917

917

First hour delivery 40°C rise First hour delivery 45°C rise

2432 2317

2524 2438

2782 2667

3040 2897

3132 3017

3390 3820

2088

3247

3629

*** SB = Basic panel - SF = Full panel

CODE

With soft jacket - Basic panel With soft jacket - Full panel

3080338

3104109 3080339 3080340 3080341 3080342 3080343 3080344 3080345 3080346 3080347

The capacity indicated in this catalogue identifies the product category. The effective capacity of the product is given in the relevant technical documentation provided with the product.

| 64

Made with FlippingBook Annual report