EN_CCR_Catalog_Compact_LINE_2026_legally checked

Customization ƒ Sliding glass lids (E profile) ƒ Smart LED, handrail lighting, light color Neutral White 4000K, Cool White 5700K, Fresh Red

Type code

visiCUBE® PA C 100 M1/L1 . PI - 1

Name Suffix: OP = OPTI Design: C = Closed (glass lids) Module: 100 = 945mm 150 = 1445mm 200 = 1940mm Temperature class:

ƒ Scanner price rail, 40 or 60mm ƒ Height adjustable wire shelves ƒ Wire divider, front-back ƒ Product dividers

ƒ Bottom bumper all around, plastic or stainless steel ƒ Wooden cladding with or without stainless steel bumper ƒ Extended cabinet feet (90mm) with or without bottom plinth panel all around ƒ Castors, 2 rotating and 2 covered wheels or 4 rotating wheels (90 mm) incl. brakes ƒ Connectivity options to various store gateways ƒ Easy condenser access ƒ Condenser filter

M1 = -1…+1 °C / L1 = -22…-24 °C M0 = -2…0 °C / L1 = -22…-24 °C Technology: PI = Plug-In Revision index: 1

ƒ Additional temperature display ƒ Separate power cable for lighting ƒ Country specific mains cable

visiCUBE® PANO 100

visiCUBE® PANO 150

visiCUBE® PANO 200

Basic models

VISICUBE PA C 100 M1/L1.PI-1 VISICUBE PA C 100 M0/L1.PI-1

VISICUBE PA C 150 M1/L1.PI-1 VISICUBE PA C 150 M0/L1.PI-1

1840

840

1340

760

6

6

1945

1445

945

940

CHILLER

FREEZER

260 150

A B

260 260

A A

M1 / L1 M0 / L1

visiCUBE® PANO (Side view)

visiCUBE® PANO 100 (Front view) 260 A 260 A CHILLER FREEZER

visiCUBE® PANO 150 (Front view) M1 / L1 260 A 260 A CHILLER FREEZER

visiCUBE® PANO 200 (Front view)

M1 / L1 M0 / L1

150

B

260

A

M0 / L1

150

B

260

A

1:10 08.05.2025 4230730

1:10 08.05.2025 4236000

visiCUBE® PANO switchable 2 CO2OLTEC Kältetechnik Deutschland GmbH

Unit [°C]

100

150

200

CO2OLTEC Kältetechnik Deutschland GmbH

-1…+1 / -2…0 -22…-24

-1…+1 / -2…0 -22…-24

-1…+1 / -2…0 -22…-24

Temperature

R290

R290 1445

R290 1945 940 910 364 2,46

Refrigerant

[mm] [mm] [mm]

945 940 910 166 1,29

Width Depth

940 910 265 1,87

Height (without castors)

[l]

Volume (L1 / M1) Total display area

[m²]

Energy consumption** Freezer mode (L1) Chiller mode (M1 / M0) Average heat dissipation Freezer mode (L1) Chiller mode (M1 / M0)

[kWh/d]

7,69 4,46 / 4,62

11,29 6,87 / 7,29 470 286 / 304

13,56 7,87 / 8,19 565 327 / 341

[W]

320 186 / 193 M1 / M0 L1

M1 / M0 L1

M1 / M0 L1

Temperature class*

* At climate class 3 according to ISO 23953 | ** Measured in accordance with the applicable EU delegated regulation 1 Energy Labels might change depending on cabinet configuration and are based on R290 plug-in refrigerant technology 2 All technical data includes LED lighting consumption where applicable consumption where applicable

Compact Line 2026 71

Made with FlippingBook - professional solution for displaying marketing and sales documents online