910117_eMobility Brochure

Our CV Standard Battery System for commercial vehicles: the heart of every vehicle

The Webasto CV Standard Battery System was developed according to the requirements in the commercial vehicle market and is therefore suitable as a traction battery for a wide range of vehicles.  Scalable CV Standard Battery System with a system configuration of 400 V and 800 V as well as up to 630 kWh  Up to 18 CV Standard Battery Systems can be interconnected with the Vehicle Interface Gateway or up to 10 CV Standard Battery Systems with the Vehicle Interface Box

 Future-proofing through further development of the battery system  Vertical and horizo tal mounting positions allow flexible and easy integration

Features:

 Physical separation between high voltage and cooling connectors  Desiccant cartridges to avoid condensation over the entire product life cycle

 Integrated thermal runaway detection in each system  Integrated, state-of-the-art pressure equalization  Isolation measurement, high voltage interlock and contactor monitoring included in every battery pack  Temperature, voltage and current of different subcomponents are monitored  Maintenance-free design

Norms & standards  Homologation: ECE R100, ECE R10  Transport: UN T38.3 (Transport of Dangerous Goods)  Safety: ISO 6469, ISO 26262 (ASIL C)  Environment: ISO 20653 (IP67/ IP6K9K)  Vehicle Communication: CAN Bus conform to ISO 11898

Technical specifications

CV Standard Battery

Dimensions (L x W x H)

37.8 x 27 x 11.9 in (960 x 686 x 302 mm)

Weight

650 lbs. (295 kg) ** per pack

Installed energy Nominal capacity Depth of discharge

35 kWh

 Company Standards: LV 123, LV 124  EMC: ISO 11452, ISO 7637, CISPR 25

99 Ah

80 / 90%

Voltage range Energy density

280 V – 400 V (~ 350 nominal) ~203 Wh / l, >118 Wh / kg

System requirements and the environment  Optimized for vehicle classes M1, M2, M3, N1, N2 & N3 (EC Directive 2007/46)  Designed for an ambient temperature of -30 °C to 60 °C, 3,500 meters above sea level and 0 – 100 % humidity

Continuous use (CH / DCH) (@25 °C, SoC dependent) Peak power (CH / DCH) (10s, @25 °C, SoC dependent) Lifetime (DoD, temperature, and C-rate dependent)

50 / 56 kW

113 / 112 kW

Up to 3.000 cycles*

Calendric lifetime

Up to 8 years

Volume flow Pressure loss

10 l/min. < 50 mbar

Cell type

prismatic NMC

Operating temperature

-22 °F to 140 °F 3,500 meters above sea level 0 - 100% humidity

9