Summit Power Brochure

Discover the full range of Summit Power’s cutting-edge products with this brand new online brochure - a detailed overview of our full range across 20 pages, complete with summarised specifications for each product.

Comprehensive p wer solutions across the UK

Stage V Generator Hire | Battery Energy Storage System Hire Fuel Management | Loadbank Hire | Electrical Distribution | Cabling

www.summitpower.co.uk

Summit Power is a full-service temporary power hire specialist. We offer the latest, most sustainable, Stage V generators and battery energy storage systems , backed by extensive expertise and experience in the temporary power industry.

www.summitpower.co.uk

We are ‘Switched On’ to delivering the best possible service for our customers – making sure they get the temporary power support they need, when they need it, wherever they need it. We are part of the Summit Rentals Group, which also operates the highly-successful national powered access and telehandler hire specialist Summit Platforms. As such, we have the operational expertise and financial strength to provide our customers with the industry-leading temporary power equipment and service they value. In addition, our hybrid power solutions, partnering generators with battery back-up, which can significantly reduce our customers’ energy costs and CO 2 emissions, while optimising silent operation in sensitive locations. These advantages are supported by a range of highly responsive services, including remote monitoring, fuel management, loadbank hire, accessories supply and electrical distribution systems. We also provide a temporary power project design and fulfilment service for all needs, from small single sites to large and complex multi-site programmes.

3

Stage V Generators Exclusive Stage V only generator fleet from 20kVA – 500kVA to provide you with maximum efficiency  and emission compliance.

www.summitpower.co.uk

4

Stage V Generators

20kVA

40kVA

16 kw 50 Hz 3.8 l/h 26 hrs 62 dB 788 kg

42 kw 50 Hz 8.3 l/h 22 hrs 67 dB

Power Capacity

Power Capacity

50 / 60Hz available

50 / 60Hz available

Fuel Consumption at 70% 50Hz Running hours internal tank at 70%

Fuel Consumption at 70% 50Hz Running hours internal tank at 70%

Noise at 7 metres

Noise at 7 metres

1,100 kg

Weight

Weight

Dimensions (LxWxH) 2.15 x 1.02 x 1.33 m

Dimensions (LxWxH) 2.30 x 1.13 x 1.58 m

60kVA

100kVA

53 kw 50 Hz

90 kw 50 Hz 17 l/h 25 hrs 67 dB

Power Capacity

Power Capacity

50 / 60Hz available

50 / 60Hz available

10.8 l/h

Fuel Consumption at 70% 50Hz Running hours internal tank at 70%

Fuel Consumption at 70% 50Hz Running hours internal tank at 70%

25 hrs 65 dB

Noise at 7 metres

Noise at 7 metres

1,500 kg

1,680 kg

Weight

Weight

Dimensions (LxWxH) 2.55 x 1.13 x 1.64 m

Dimensions (LxWxH) 2.55 x 1.13 x 1.64 m

5

Stage V Generators

100kVA - Silent

150kVA

90 kw 50 Hz 17 l/h 18 hrs 55 dB

136 kw 50 Hz 25 l/h 24 hrs 67 dB 3,390 kg

Power Capacity

Power Capacity

50 / 60Hz available

50 / 60Hz available

Fuel Consumption at 70% 50Hz Running hours internal tank at 70%

Fuel Consumption at 70% 50Hz Running hours internal tank at 70%

Noise at 7 metres

Noise at 7 metres

2,080 kg

Weight

Weight

Dimensions (LxWxH) 2.60 x 1.13 x 1.80 m

Dimensions (LxWxH) 3.90 x 1.13 x 2.39 m

150kVA - Silent

200kVA

150 kw

160 kw

Power Capacity

Power Capacity

50 Hz

50/60 Hz 29.7 l/h

50 / 60Hz available

50 / 60Hz available

22.2 l/h

Fuel Consumption at 70% 50Hz Running hours internal tank at 70%

Fuel Consumption at 70% 50Hz Running hours internal tank at 70%

27 hrs 58 dB

20 hrs 66 dB

Noise at 7 metres

Noise at 7 metres

4,480 kg

3,045 kg

Weight

Weight

Dimensions (LxWxH) 3.90 x 1.13 x 2.30 m

Dimensions (LxWxH) 4.00 x 1.2 x 2.00 m

www.summitpower.co.uk

6

from 20kVA to 500kVA

300kVA

264 kw

Power Capacity

50/60 Hz 50.83 l/h

50 / 60Hz available

Fuel Consumption at 70% 50Hz Running hours internal tank at 70%

18 hrs 68 dB

Noise at 7 metres

5,100 kg

Weight

Dimensions (LxWxH) 4.43 x 1.70 x 2.40 m

500kVA

440 kw

Power Capacity

50/60 Hz 83.1 l/h

50 / 60Hz available

Fuel Consumption at 70% 50Hz Running hours internal tank at 70%

12 hrs 75 dB

0333 034 9433

Noise at 7 metres

6,970 kg

Weight

enquiries@summitpower.co.uk

Dimensions (LxWxH) 4.98 x 1.90 x 2.55 m

7

Battery Energy Storage Plug and play Hybrid or stand-alone applications which can support your site needs and reduce operating fuel costs, meet emission regulations or support in reducing noise in sensitive surroundings.

www.summitpower.co.uk

8

Battery Energy Storage

30kVA

45 kWh 30 kVA

Useable Energy Capacity

Power Rating Charge time

4 hrs

230-400 VAC

AC Output Voltage (50hz)

1,210 kg

Weight

1.55 x 1.25 x 1.61 m

Dimensions (LxWxH)

1 x 125A 3 Φ, 1 x 63A 3 Φ

Input Connections Output Connections

1 x 125A 3 Φ, 1 x 63A 3 Φ , 1 x 32A 3 Φ, 2 x 32A 1 Φ, 1 x 16A 1 Φ

45kVA

60 kWh 45 kVA

Useable Energy Capacity

Power Rating Charge time

4 hrs

230-400 VAC

AC Output Voltage (50hz)

2,000 kg

Weight

2.15 x 1.25 x 1.90 m

Dimensions (LxWxH)

1 x 125A 3 Φ, 1 x 63A 3 Φ

Input Connections Output Connections

1 x 125A 3 Φ, 1 x 63A 3 Φ , 1 x 32A 3 Φ, 10 x 32A 1 Φ, 2 x 16A 1 Φ

45kVA

90 kWh 45 kVA

Useable Energy Capacity

Power Rating Charge time

4 hrs

230-400 VAC

AC Output Voltage (50hz)

2,300 kg

Weight

2.15 x 1.25 x 1.90 m

Dimensions (LxWxH)

1 x 125A 3 Φ, 1 x 63A 3 Φ

Input Connections Output Connections

1 x 125A 3 Φ, 1 x 63A 3 Φ , 1 x 32A 3 Φ, 10 x 32A 1 Φ, 2 x 16A 1 Φ

9

Battery Energy Storage

250kVA

575 kWh 250 kVA

Useable Energy Capacity

Power Rating Charge time

3 hrs

400 VAC 12,000 kg

AC Output Voltage (50hz)

Weight

2.99 x 2.44 x 2.90 m 500A rated busbar, 1 x 125A 3 Φ , 1 x 63A 3 Φ , 1 x 32A 3 Φ

Dimensions (LxWxH)

Output Connections

Flybrid

85 kWh

Peak power rating Peak power rate Reactive Power

2,500 kW/s

144 kVAr 50/60 Hz 400/480v

Frequency

AC Output Voltage (50hz)

Load reaction time < 30 ms Noise at 7 metre (60% SoC) 58 dB Weight 1,280 kg Dimensions (LxWxH)

1.65 x 1.3 x 1.59 m

1 x 125A 3 Φ

Output Connections

0333 034 9433

enquiries@summitpower.co.uk

www.summitpower.co.uk

www.summitpower.co.uk

10

Hybrid Power

Working together to manage load demand results in Smaller Generators on hire Dramatically lower emissions Lower fuel costs Reduced maintenance interruptions

What does Hybrid Power Setup look like?

Generator

Battery storage

Solar

Optional

Canteen

WC

Security

O ce

Lighting

EV charging

How much can i potentially save?

Hybrid Power is greener and can be cheaper

Hybrid Power works best

Where power is needed 24/7

When noise is a concern

Lower emission targets

Estimated savings based an operating cycle of 50% battery storage / 50% generator

11

Fuel Management

800L

Providing Diesel, HVO and Adblue as a complete managed solution, ensuring site power and operations remain uninterrupted.

769 Litres

Safe Fill Level

DEF

Fuel Type

471 kg

Weight, Tare

1,307 kg

Weight, Laden

Dimensions (LxWxH) 1.64 x 1.1 x 1.3 m

1000L

1600L

2500L

870 Litres

Safe Fill Level 1,569 Litres Fuel Type DEF Weight, Tare 731 kg Weight, Laden 2,436 kg Dimensions (LxWxH) 2.61 x 1.18 x 1.3 m

Safe Fill Level 2,442 Litres Fuel Type Dual Fluid Weight, Tare 1,102 kg Weight, Laden 3,443 kg Dimensions (LxWxH) 2.3 x 1.89 x 1.3 m

Safe Fill Level

Diesel 483 kg

Fuel Type

Weight, Tare

1,223 kg

Weight, Laden

Dimensions (LxWxH) 1.49 x 1.15 x 1.29 m

3000L

4500L

9000L

Safe Fill Level 2,700 Litres Fuel Type Diesel Weight, Tare 868 kg Weight, Laden 3,175 kg Dimensions (LxWxH) 2.23 x 1.52 x 1.27 m

Safe Fill Level 4,293 Litres Fuel Type Diesel Weight, Tare 1,335 kg Weight, Laden 4,994 kg Dimensions (LxWxH) 2.65 x 2.3 x 1.29 m

Safe Fill Level 8,100 Litres Fuel Type Diesel Weight, Tare 2,810 kg Weight, Laden 10,505 kg Dimensions (LxWxH) 2.52 x 2.3 x 2.4 m

www.summitpower.co.uk

12

Load Banks

100kw

400kw

Resistive 400-480v Sigma LT

Resistive 400-480v Sigma LT

Load Type

Load Type

Voltage Control Weight

Voltage Control Weight

250 kg

550 kg

Connection Type Powerlock Connections (1 per Φ ) Dimensions (LxWxH) 1.03 x 0.74 x 1.2 m

Connection Type Powerlock Connections (2 per Φ ) Dimensions (LxWxH) 1.42 x 1.035 x 1.66 m

500kVA

1000kw

Resistive / Reactive

Resistive 400-480v Sigma 2 1,290 kg

Load Type

Load Type

400-480v Sigma 2 2,650 kg

Voltage Control Weight

Voltage Control Weight

Busbar Connection

Busbar Connection

Connection Type

Connection Type

Dimensions (LxWxH) 2.225 x 1.48 x 2.06 m

Dimensions (LxWxH) 2.225 x 1.48 x 2.06 m

Resistive & Resistive/Reactive Load banks available to support testing, commissioning or maintenance of your critical applications.

enquiries@summitpower.co.uk

0333 034 9433

13

Mains Distribution Units (MDU)

From 250A to 2000A Our MDU’s are suitable for use on any temporary power installation and are manufactured to IP55 rating as standard. Supplied within a robust heavy duty galvanised crash frame this can be transported easily within site locations.

250A MDU

400A MDU

800A MDU

Rating 250A Incomer 250A 3 Φ

Rating 400A Incomer 400A 3 Φ

Rating 800A Incomer 800A 3 Φ

1 x 125A 3 Φ 2 x 63A 3 Φ 2 x 32A 3 Φ 2 x 32A 1 Φ

2 x 125A 3 Φ 2 x 63A 3 Φ 2 x 32A 3 Φ 2 x 32A 1 Φ

1 x 400A 3 Φ 2 x 125A 3 Φ 2 x 63A 3 Φ 2 x 32A 1 Φ

Outgoing

Outgoing

Outgoing

95kg

108kg

252kg

Weight

Weight

Weight

1250A MDU

2000A MDU

2000A MDU

Rating 1,250A Incomer 1,250A 3 Φ

Rating 2,000A Incomer 2 x 1,000A 3 Φ

Rating 2,000A Incomer 2000A 3 Φ

2 x 400A 3 Φ 2 x 125A 3 Φ 2 x 63A 3 Φ

4 x 630A 3 Φ 2 x 125A 3 Φ 2 x 63A 3 Φ

4 x 630A 3 Φ 2 x 125A 3 Φ 2 x 63A 3 Φ

Outgoing

Outgoing

Outgoing

566kg

721kg

741kg

Weight

Weight

Weight

www.summitpower.co.uk

14

Event Distribution

Our event distribution is designed to support the needs for all event requirements.

Integrated lifting handles for easy handling & transportation around site.

Suitable for indoor & outdoor use.

32A

63A

125A

Rating 32A Incomer 32A 3 Φ

Rating 63A Incomer 63A 3 Φ

Rating 125A Incomer 125A 3 Φ

1 x 63A 3 Φ 4 x 32A 3 Φ 6 x 32A 1 Φ 6 x 16A 1 Φ

6 x 32A 1 Φ 6 x 16A 1 Φ 6 x 13A 1 Φ

1 x 32A 3 Φ 6 x 32A 1 Φ 6 x 16A 1 Φ

Outgoing

Outgoing

Outgoing

27kg

23kg

38kg

Weight

Weight

Weight

400A

400A

Rating

400A 3 Φ

Incomer

400A 3 Φ Powerlock (unprotected) 3 x 125A 3 Φ

3 x 63A 3 Φ 6 x 32A 3 Φ 3 x 32A 1 Φ 3 x16A 1 Φ

Outgoing

118kg

Weight

enquiries@summitpower.co.uk

0333 034 9433

15

Cabling

Single Phase Cable

16A to 125A Available with suitably rated Powerlock or lugged connections.

Available in various lengths from 5m up to 50metres.

Three Phase Cable

16A to 125A Available with suitably rated Powerlock or lugged connections.

Available in various lengths from 5m up to 50metres.

Single Core Cable

150mm & 240mm Available with suitably rated Powerlock or lugged connections.

Available in various lengths from 3m up to 50metres.

Cable Protection Cable protection ramps for pedestrian and vehicle traffic.

www.summitpower.co.uk

16

Services

Fuel Management Providing Diesel, HVO, Ad Blue fuel & exhaust additives to ensure power is available at all times Equipment Installation & Commissioning On site setup services for any of the equipment hired from Summit Power

Remote Monitoring 24/7 Equipment Monitoring available to ensure maximum availability of power

Load Testing

On-site load testing services inclusive of reporting

Transportation

0333 034 9433

Delivery, Collection & Loading capability across any site requirement

enquiries@summitpower.co.uk

17

Powered Access Hire

Summit Platforms, a part of Summit Rentals Group, is a national provider of powered access and telescopic handler hire, as well as machine sales, contract hire and associated training. We are dedicated to providing the latest in modern equipment accompanied with the highest levels of customer service.

Boom Hire

Telehandlers

Contact your local branch for a free site survey

Glasgow.. . . . . . Newcastle. . . . . . Wakefield. . . . . . Haydock.. . . . . . East Midlands. . . Birmingham. . . . Bristol.. . . . . . . . Portsmouth.. . . . London West.. . . London East. . . .

Scissor Lift Hire

01698 678 050 0191 6070 909 01924 976 000 01942 559 166 01530 447 000 0121 227 4433 01173 326 640 02392 006 577 01923 979 388 01708 988 100

Low Level Access

IPAF training

Look out for Low and Zero emission platforms. We all have a part to play in reducing carbon emissions

You can use your Summit Power account to hire from Summit Platforms Making hire easy

www.summitplatforms.co.uk

Comprehensive power solutions across the UK

0333 034 9433 enquiries@summitpower.co.uk

Summit Power Melbourne Road, Lount, Leicestershire. LE65 1RS.

www.summitpower.co.uk

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20

Made with FlippingBook Ebook Creator