Sheet 2000-7 Page 2
motor shaft specifications
diameter, in. a
length, in. b
motor frame no.
KWY,
Blower
drip- proof 145T 145T 182T 184T 213T 324T 326T
RD, or
drip- proof 0.875 0.875
drip- proof 2.250 2.250 2.750 2.750 3.375 5.250 5.250 5.250 c 1.875 2.250 2.250 2.250 2.750 2.750 3.375 3.375 4.000 4.625 4.625 5.250 5.250 5.250 2.750 3.375 3.375 3.375 4.000 4.625 4.625 5.250 5.250 5.875 5.500 c 6.750 c 6.750 c 2.250 6.750 c 2.250 3.000 c 6.750 c 6.750 c 2.750 2.750 7.000 c
designation
TEFC
FLAT
TEFC
TEFC
2310-19/1- _ 2D 2310-26/1- _ 3D 2310-26/1- _ 5D
145T 182T 184T 213T 215T 324T 326T
KWY KWY KWY KWY KWY KWY KWY FLAT KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY KWY
0.875
2.250 2.750 2.750 3.375 3.375 5.250 5.250 5.250 c 1.875 2.250 2.250 2.750 2.750 3.375 3.375 4.000 4.000 4.625 4.625 5.250 5.250 5.250 3.375 3.375 3.375 4.000 4.000 4.625 4.625 5.250 5.250 5.875 5.500 c 6.750 c 6.750 c 2.250 6.750 c 2.750 2.750 6.000 c 7.000 c 2.750 2.750 7.000 c
1.125 1.125
1.125
2310-35/1- _ 7.5D 2310-21/1- _ 10D 2310-47/1- _ 40D 2310-47/1- _ 50D 2312-11/4- _ .5D 2312-19/1- _ 1D 2312-19/1- _ 1.5D 2312-19/1- _ 2D
1.125 1.375 2.125 2.125 0.625 0.625 0.875 0.875 0.875 1.125 1.125 1.375 1.375 1.625 1.875 1.875 2.125 2.125 2.125 1.125 1.375 1.375 1.375 1.625 1.875 1.875 2.125 2.125 2.375 0.625 0.875 0.875 0.875 0.875 0.875 0.875 0.875 0.875
1.375 1.375 2.125 2.125 0.625 0.625 0.875 0.875
56 56
56 56
143T 145T 145T 182T 184T 213T 215T 256T 284T 286T 324T 324T 326T 184T 213T 213T 215T 254T 284T 286T 324T 326T 364T
143T 145T 182T 184T 213T 215T 254T 256T 284T 286T 324T 324T 326T 213T 215T 215T 254T 256T 284T 286T 324T 326T 364T
2312-26/1- _ 3D
1.125
2312-26/1- _ 5D 2312-35/1- _ 7.5D 2312-35/1- _ 10D 2312-21/1- _ 15D f 2312-41/1- _ 20D f 2312-41/1- _ 25D f 2312-41/1- _ 30D f 2312-41/1- _ 40D f 2312-47/1- _ 40D 2312-47/1- _ 50D 2412-D- _ 7.5D 2412-D- _ 10D 2412-F- _ 10D 2412-F- _ 15D 2412-F- _ 20D 2412-G- _ 25D 2412-G- _ 30D 2412-G- _ 40D 2412-G- _ 50D 2412-G- _ 60D 2316-14/2- _ 1D 2316-14/2- _ 1.5D 2316-17/2- _ 1.5D 2316-19/1- _ 2D 2316-17/2- _ 2D 2316-19/1- _ 3D 2316-26/1- _ 3D 2316-17/2- _ 3D 2316-24/2- _ 3D 2316-28/1- _ 5D 2316-26/1- _ 5D 2316-24/2- _ 5D
1.125 1.375 1.375 1.625 1.625 1.875 1.875 2.125 2.125 2.125 1.375 1.375 1.375 1.625 1.625 1.875 1.875 2.125 2.125 2.375 0.625 0.875 0.875
56
56
RD RD RD
143T 143T
143T 143T
145T 145T 145T 145T 145T 145T 182T 182T 182T
145T 145T 182T 182T 182T 182T 184T 184T 184T
KWY
0.875 0.875
RD
KWY
1.125
RD/KWY
1.125 1.125 1.125 1.125 1.125 1.125
RD RD
KWY KWY
1.125 1.125 1.125
RD
WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.
Made with FlippingBook flipbook maker