Sheet 2300-6 Page 4
Threaded Outlet, Gasket and Hardware
Assembly SW Outlet, Gasket and Hardware
Assembly SW Inlet, Gasket and Hardware
Threaded Inlet, Gasket and Hardware
Inlet Guard and Hardware
Nominal pipe size in inches
Blower
Inlet
Outlet
Assembly
Assembly
Assembly
2332-28/2-_10 2332-28/2-_15 2332-21/2-_20 2332-21/2-_25 2332-21/2-_30 2332-21/2-_40 2332-33/2-_50 2332-33/2-_60 2332-41/2-_75
8 8
6 6 8 8 8 8
1-5201-9 1-5201-9 1-5201-5 1-5201-5 1-5201-5 1-5201-5 1-5201-10 1-5201-10 1-5201-12
1-5200-9 1-5200-9 1-5200-6 1-5200-6 1-5200-6 1-5200-6 1-5200-5 1-5200-5 1-5200-10
1-5204-5 1-5204-5 1-5202-3 1-5202-3 1-5202-3 1-5202-3 1-5202-7 1-5202-7 1-5202-13
1-5203-5 1-5203-5
10
10 10 10 12 12 16
12 12 12
2332-41/2-_100 2332-41/2-_125
16 16
16 16
1-5201-12 1-5201-12
1-5200-10 1-5200-10
1-5202-11 1-5202-11
2338-41/2-_75 2338-41/2-_100
16 16
12 12
1-5201-12 1-5201-12
1-5200-10 1-5200-10
1-5202-13 1-5202-13
2344-28/3-_15 2344-28/3-_20 2344-21/2-_30
8 8
6 6 8
1-5201-9 1-5201-9 1-5201-5
1-5200-9 1-5200-9 1-5200-6
1-5204-5 1-5204-5 1-5202-3
1-5203-5 1-5203-5
10
2344-21/2-_40 2344-21/2-_50
10 10
8 8
1-5201-5 1-5201-5
1-5200-6 1-5200-6
1-5202-3 1-5202-3
" SW " means sleeve or weld. A flexible rubberized sleeve (Bulletin 2947) can be slipped over an SW connection and clamped to prevent leaks. A flexible connection dœs not transmit vibrations or stresses as do welded or threaded connections. Blowers are not designed for imposed loads from hard pipe connections and should not be "hard" piped except under unusual circumstances.
Fig. 2.
Fig. 1.
Fig. 3.
Inlet or outlet adapters are not included as standard supply and must be specified at an additional cost.
Discharge Connections A threaded (female) flange (Fig. 1) is available with blowers of 6" and smaller discharge pipe size. An SW connection (Fig. 2) is available for 8" and larger, or may be specified for smaller sizes (Fig. 3). Inlet Connections An SW inlet (unthreaded, Fig. 2) for sleeve or welding connection is availabe. A threaded female inlet (Fig. 3) may be specified for 3" through 6" inlets. For an open inlet, an inlet guard should be specified (Fig. 1). Blowers should not be operated without inlet protection. WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.
CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237
Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com
Made with FlippingBook flipbook maker