Combustion Catalog | Fives North American

Sheet 2300-11 Page 4

discharge overall dimension

discharge overall dimension

To fully ascertain overall clearances, check the dimension combinations shown at right for the particular discharge position selected.

position

height

width

position

height

width

1

G+K F+G

F+K E+K

3 4

E+G G+K

F+K E+K

2

All dimensions are in inches. Dimensions shown apply only to blowers with T-frame motors. Consult North American for dimensions of blowers with other motors.

Blower, designation*

A

B

C

D

D1

E

F

G

H

J

K

N

P

S

T

V

2332-38/2-_75C 2332-38/2-_100C 2332-38/2-_125C 2332-41/2-_75C 2332-41/2-_100C 2332-41/2-_125C 2338-41/2-_75C 2338-41/2-_100C 2344-38/2-_75C 2344-38/2-_100C 2344-38/2-_125C

18 16 5⁄8 18 16 5⁄8 18 16 5⁄8 12 23 1⁄8 16 23 1⁄8 16 23 1⁄8 12 23 1⁄8 12 23 1⁄8 18 16 5⁄8 18 16 5⁄8 18 16 5⁄8

22 ½ 22 ½ 22 ½ 23 ½ 23 ½ 23 ½ 23 ½ 23 ½ 22 ½ 22 ½ 22 ½

88

2 5⁄8 4 ½ 4 ½ 2 5⁄8 4 ½ 4 ½ 2 5⁄8 4 ½ 2 5⁄8 4 ½

29 7⁄8 29 7⁄8 29 7⁄8 34 ¼ 34 ¼ 34 ¼ 34 ¼ 34 ¼ 29 7⁄8 29 7⁄8 29 7⁄8

43 43 43

31 ½ 31 ½ 31 ½

18 ¼ 18 ¼ 18 ¼ 25 1⁄8 25 1⁄8 25 1⁄8 25 1⁄8 25 1⁄8 18 ¼ 18 ¼ 18 ¼

36 ½ 36 ½ 36 ½ 37 ½ 37 ½ 37 ½ 37 ½ 37 ½ 36 ½ 36 ½ 36 ½

25 ½ 25 ½ 25 ½ 33 ¾ 33 ¾ 33 ¾ 33 ¾ 33 ¾ 25 ½ 25 ½ 25 ½

72 5⁄8 72 5⁄8 72 5⁄8

1 ¼ 1 ¼ 1 ¼ 1 ¾ 1 ¾ 1 ¾ 1 ¾ 1 ¾ 1 ¼ 1 ¼ 1 ¼

18 9 ¼ 18 9 ¼ 18 9 ¼ 16 9 1⁄8 16 9 1⁄8 16 9 1⁄8 16 9 1⁄8 16 9 1⁄8 18 9 ¼ 18 9 ¼ 18 9 ¼

3 ¼ 3 ¼ 3 ¼ 3 ¾ 3 ¾ 3 ¾ 3 ¾ 3 ¾ 3 ¼ 3 ¼ 3 ¼

89 7⁄8 89 7⁄8

97

50 15⁄16

38 38 38 38 38

76 76 76 76 76

98 7⁄8 98 7⁄8

44 44 44 44 43 43 43

97

98 7⁄8

88

31 ½ 31 ½ 31 ½

72 5⁄8 72 5⁄8 72 5⁄8

89 7⁄8 86 ¾

1 3⁄8

* Explanation of designation: 2304-11/1-_.3C means 2300 series, 4 osi pressure, inner housing no. 11, 1⁄3 hp motor, coupled drive.

"SW" means sleeve or weld. A flexible rubberized sleeve (Bul- letin 2947) can be slipped over an SW connection and clamped to prevent leaks. A flexible connection dœs not transmit vibrations or stresses as do welded or threaded connections. Blowers are not designed for imposed loads from hard pipe connections and should not be "hard" piped except under unusual circumstances.

Fig. 1. Fig. 3. Inlet or outlet adapters are not included as standard supply and must be speci fi ed at an additional cost. Fig. 2.

Inlet Connections: An SW inlet (unthreaded, Fig. 2) for sleeve or welding connection is availabe. A threaded female inlet (Fig. 3) may be speci- fied for 3" through 6" inlets. For an open inlet, an inlet guard should be specified (Fig. 1). Blowers should not be operated without inlet protec- tion.

Discharge Connections: A threaded (female) flange (Fig. 1) is available with blowers of 6" and smaller discharge pipe size. An SW connection (Fig. 2) is available for 8" and larger, or may be specified for smaller sizes (Fig. 3).

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com