Dimensions 2400 Page 2
12 1 /
11 / 16 dia. 4 holes
12 1 /
11 / 16 dia. 6 holes
4
2
2
4
13
13 13
6
Inlet
Motor Inlet
Motor
13
12 1 /
45°
12 1 /
4
4
2
20 3 /
21 3 /
21
3 /
2
2
W
4
16
16
8 1 /
8 2
1 /
8 1 /
8 2
1 /
4
4
Foundation Plan
Foundation Plan
No. 2 1 /
2
45°
Outlet
Outlet
V
No. 2
20" Inlet nominal pipe size
20" Inlet nominal pipe size
No. 3
Shaft & Coupling guard
25 13 /
16 rad.
45°
No. 1 1 /
No. 3 1 /
2
2
23 1 / 2 rad.
28 1 / rad.
8
45°
23 3 /
8
39
No. 1 Discharge
30 7 /
16 rad.
A–Outlet nominal pipe size
A–Outlet nominal pipe size
16 dia. holes
11 /
2 1 /
4
2
6 1 /
8 5
1 /
6 1 /
8 5
1 /
2
2
2
21
3 /
21
3 /
X 1
20
3 /
X
12 1 /
12
1 /
9 3 /
8
1 /
9 3 /
8
1 /
16
16
4
4
4
4
8
4
8
40 5 /
62 1 /
13 13
8
4
42 1 /
64 1 /
28 5 /
2
8
8
43 1 /
65 1 /
F
2
8
Typical Inlet Side
Direct Drive
Coupled Drive
Standard impellers are aluminum. They can be furnished in steel or stainless steel at additional cost.
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .
Approximate Weight, lb
Dimensions in inches
Blower
X
X 1
Direct Drive Coupled Drive
Designation
A
F
V
W
DP
TEFC DP TEFC
DP
TEFC
DP
TEFC
42 1⁄16 42 1⁄16 44 3⁄16 44 3⁄16
42 1⁄16 42 1⁄16 46 11⁄16 46 11⁄16 46 11⁄16
8 8
– – – – –
– – – –
– – – – – – – – – – – – –
– – – –
1375 1470 1500 1575 1625 1485 1515 1590 1640 1725 1520 1595 1645
1465 1695 1785 1565 1790 1885
2408-G-_20 2408-G-_25 2408-G-_30 2408-G-_40 2408-G-_50 2408-H-_50D 2412-G-_25 2412-G-_30 2412-G-_40 2412-G-_50 2412-G-_60 2416-G-_30 2416-G-_40 2416-G-_50
18 20 24 24
13 11⁄16 13 11⁄16 13 11⁄16
1615
1820 1935
1730 1895 2050
1 ½
1795
1945
2115
24* 44 3⁄16
½
For dimensions refer to Sheet 2400-1.
16 18 20 24 24 16 18 20
42 1⁄16 42 1⁄16 42 1⁄16 44 3⁄16 44 3⁄16 42 1⁄16 42 1⁄16 42 1⁄16
42 1⁄16 42 1⁄16 42 1⁄16 46 11⁄16 46 11⁄16 42 1⁄16 42 1⁄16 42 11⁄16
8 8 8
– – – – – – – –
– – –
– – –
1580 1800 1895 1630 1830 1945 1745 1905 2060 1940 2040 2255 1635 1835 1950 1810 1955 2125
1 ½ 8 7⁄8
13 11⁄16 13 11⁄16
½
1 ¾
8 8 8
– –
– –
1750 1815
1910 2065 1960 2130
1 ½
½
* For an average situation, a 30" discharge pipe is recommended but length of run should determine size.
To order, specify:
Motor Type L = Less motor T = TEFC
WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.
Blower Designation
Code Letter for Drive D = Direct
Horsepower 7.5 = 7 1 / 2
2412-F T 20 D Blower and include in description blower discharge position, also type of inlet and discharge. Enter motor (from Blower and Motor Price List) on next line. Example: 2412-F-T20D Direct Drive Blower with #3 discharge, with T20-C36T1SC 20 hp 230-460/3/60 TEFC Motor mounted.
CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237
Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com
Made with FlippingBook flipbook maker