Combustion Catalog | Fives North American

North American 2408-H-_50D Blower Specifications, Dimensions

Sheet 2400-1

The 2408-H-50D Direct Drive Blower, rated 13 100 cfm at 8 osi with 1.15 service factor, is ideally suited as a combustion air source for large single burner installations, such as Type G Automatic Burners. Motor speed is 1800 rpm.

SPECIFICATIONS

At 100% of motor rating

At 115% of motor rating

Pipe size, in.

Blower

Motor

Volume

Volume

Pressure

Volume

Volume

Pressure

Designation

hp

cfm

cfh

osi

cfm

cfh

osi

Inlet

Outlet

2408-H-_50D

50

10 800

648 000

10

13 100

786 000

8

20

24

Silencer Designation: 2936-20-H* Filter Designation: 2921-2003-12/H* Filter-Silencer Designation: 2941-2003-12/H* * For the complete part number add a "W" for washable or "T" for throwaway.

DIMENSIONS

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COM- BUSITON, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .

Weight, with drip proof motor, 1650 lb; with TEFC motor, 1900 lb.

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com

Made with FlippingBook flipbook maker