Combustion Catalog | Fives North American

Pressures | Hot Air Blowers

Bulletin 2600 Page 4

SUCTION AND HOT AIR PRESSURES DEVELOPED BY TURBO BLOWERS

Developed blower hot air suction or pressure (osi). (P 2 )

Inlet suction developed (osi) ------------ (P v )

Nominal pressure ratings (osi) (P 1 )

BLOWER LAWS

Note that although the actual volume handled by the blower is unchanged, the equivalent volume flow rate of standard (stp) air, Q', would be:

The specific weight r per cubic foot of a gas decreases as the air temperature increases, as shown in the following formula:

Q' 2 p 2 Q' 1 = p 1 =

T 1 ( °F ) + 460 T 2 ( °F ) + 460 

P hot = P cold

Example: To find suction developed by a 16 osi blower with 600 F air, find 16 on the vertical axis and follow slanted dotted line down to 15 osi suction developed with cold air. Follow that dotted line right to intersection with 600°F curve and read 7.4 osi suc- tion on the horizontal axis below. To find the pressure developed in the same situation, follow the solid 16 osi line to intersection with the 600°F curve and read 7.8 osi on the horizontal axis.

For a given blower with fixed speed and fixed inlet and discharge resistances, the effect of a change of the specific weight, p, of the fluid being handled is:

p 2 p 1

p 2

hp 2 hp 1

p 2

=

Q 2 = Q 1

=

p 1

p 1

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com

Made with FlippingBook flipbook maker