Specifications | Ignition Transformers
4065 TRANSFORMER SPECIFICATIONS (120 V)
4065-6N1-6A/4065-5N1-6A Family
Approvals: UL, CSA
No. of secondary terminals
PRIMARY
SECONDARY
Transformer Designation
4085 Igniton cable req'd. (style)
Weight, lb
volts
volts
Enclosure
mA
hertz VA
4065-6N1-6A 4065-5N1-6A 4065-6N4-6A 4065-5N4-6A 4065-6N4X-6A 4065-5N4X-6A 4065-6N4XF-6A 4065-5N4XF-6A 4065-6N7-6A 4065-5N7-6A
120 50/60 180
6000 25/20
1
10
-C ( ¼ "Ø snap-on)
None
10 x 8
120 50/60 180
6000 25/20
1
15
-C ( ¼ "Ø snap-on)
NEMA 4
10 x 8
120 50/60 180
6000 25/20
1
15
-C ( ¼ "Ø snap-on)
NEMA 4X SST
NEMA 4X Fiberglass
120 50/60 180
6000 25/20
1
15
-C ( ¼ "Ø snap-on)
120 50/60 180
6000 25/20
1
30
-C ( ¼ "Ø snap-on)
NEMA 7
Note: The North American 4065-6N1-6A and the 4065-5N1-6A family all use the same transformer model. So either model will work in 50 or 60 Hz applications. When ordering one of these transformers use the designation that is consistent with local power specifications or for repeat orders has been previously used to avoid confusion.
DIMENSIONS inches
High voltage ¼ Ø snap-on terminal
4 7⁄16
4 7⁄8
5 7⁄8
¾ Conduit K.O. (both sides and on base plate)
5⁄16 x 6
1 ¼
6 ¾
Use standard 1/4" Ø snap-on connector for 4085 connector (type "C")
C4065-6N1-6A Family
Approvals: CSA
No. of secondary terminals
PRIMARY
SECONDARY
Transformer Designation
-A (#10 ring tongue) -A (#10 ring tongue) 4085 Igniton cable req'd. (style)
Weight, lb
volts
volts
Enclosure
mA
hertz VA
C4065-6N1-6A
120 50/60 180
6000 25/20 6000 25/20
1 1
10 15
None
C4065-6N4-6A 120 50/60 180
10 x 8 NEMA 4
Note: The North American C4065-6N1-6A transformer is similar to the 4065-6N1-6A except it has the #10 ring tongue connector on the secondary terminal.
DIMENSIONS inches
High voltage terminal with #10 thumb nut
4 7⁄16
4 7⁄8
5 7⁄8 6 ¾
¾ Conduit K.O. (both sides and on base plate)
1 ¼
5⁄16 x 6
Use #10 ring tongue connector for 4085 connector (type "A")
Bulletin 4065/4066 Page 3