Specifications | Ignition Transformers
4065 TRANSFORMER SPECIFICATIONS (120 V)
4065-6N1-10A Family
Approvals: UL, CSA
No. of secondary terminals
PRIMARY
SECONDARY
Transformer Designation
-B ( ¼ ring tongue) -B ( ¼ ring tongue) 4085 Igniton cable req'd. (style)
Weight, lb
volts
volts
Enclosure
mA
hertz VA
4065-6N1-10A 4065-6N4-10A
120 120
60 60
250 250
10 000 10 000
22 22
1 1
10 25
None
12 x 12 NEMA 4
DIMENSIONS inches
High voltage terminal ¼ -20 thread
5 3⁄8
4 3⁄8
5 3⁄16
2 ½
4 5⁄8
3 7⁄8
7 7 7⁄8
¾ Conduit K.O. (both sides and on base plate)
5⁄16 x 10
Use 1/4" ring tongue connector for 4085 connector (type "B")
4065-6N1-5B Family
Approvals: UL
No. of secondary terminals
PRIMARY
SECONDARY
Transformer Designation
4085 Igniton cable req'd. (style)
Weight, lb
volts
volts
Enclosure
mA
hertz VA
4065-6N1-5B
120
60
250
5000
22
2
15
-A ( # 10ring tongue)
None
Note: This is a center tap ignition transformer, each secondary is 5,000V to ground but is 10,000 volts between secondary terminals. Center tap ignition transformers are intended for use with dual electrode igniters which are common for direct spark lighting of oil burners, such as the North American 5025-1 oil pilot. DIMENSIONS inches
3⁄8 x 2
4 15⁄16
6 ¼
2 9⁄16
4 7⁄8
6 7⁄8 7 5⁄8
3 3⁄8
5⁄16 x 8
¾ Conduit K.O. (both sides)
Use #10 ring tongue connector for 4085 connector (type "A")
Bulletin 4065/4066 Page 4
Made with FlippingBook flipbook maker