Repair Instructions 1444A Page 2

Description

Part Number

Rubber Seal and Quick

R950-5016

Release Valve (QRV) Kit including instructions and illustrations

Qty

Part Name

4 2 2 2

Solenoid "O" Rings (2 req'd) Cylinder "O" Rings (1 req'd)

(a) "O" Ring Piston Seal (Old Style) (a) U-Cup Piston Seal (New Style) End Cover Gasket (1 req'd) (b) Subplate Gasket (New Style) (b) Subplate Gasket (Old Style) QRV Cover Insert (1 req'd)

1

"O" Ring for Air Spring Return (N/A)

2

1 1

2 2 2 2 2 2 1

QRV Covers (2 req'd)

(c) QRV Diaphragm

(c) QRV Plug

Cover "O" Ring (2 req'd)

QRV Seat (N/A)

(c) "O" Ring for Seat (N/A)

1

Grease (2 Grams)

* Parts included in Repair Kit requiring replacement.

(a) A quantity of one (1) of the seals is required depending on the solenoid valve style being repaired. The spring return side of the ceram valve dœs not have piston seals, therefore only the piston seal on the solenoid side of the valve requires replacement. Replace the worn seal with a new one of the same type. (b) A quantity of one (1) of the subplate gaskets is required depending on the solenoid valve style being repaired. Replace the worn subplate gasket with a new one of the same type. (c) The QRV diaphragm or the QRV plug is used when rebuilding the QRV on the solenoid side of the ceram valve depending on the style. If the ceram valve dœs not have a removable QRV seat, install the green diaphragm in place of the gray one. If there is a removable QRV seat, discard seat and "O" ring and install the QRV plug and new "O" ring. The spring return side dœs not require a diaphragm or plug.

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com