Combustion Catalog | Fives North American

Bulletin 1447 page 3

POSITION INDICATOR SWITCH SPECIFICATIONS Voltage 110 V ac Switch rating 3 amps Power consumption 3 mA Ambient temperature range –4°F to 140°F

The North American 1447 can be ordered with two-position indi- cation switches only. Single position is not available. Specify -LL after the part number. Example: 1447-2-LL. The position indicator consists of two micro-switches with roller arms. Each switch is mounted on a carrier. Separate threaded spindles enables them to be independently adjusted for a max- imum stroke of 20 mm. The unit is mounted on a plastic base that can be rotated 360 degrees. The complete assembly fits under a transparent hood which fits on the base plate. Two PG 9 cable glands are supplied for the electrical connections. Integral LED indicators show whether the circuit is open (red LED) and that the system voltage is present (green LED). (See Figure 1 for electrical wiring diagram.)

OPEN

CLOSE

1

1

2

2

3

3

4 OPEN 3 OPEN

2 CLOSED 1 CLOSED

Figure 1 .

DIMENSIONS inches

LL OPTION

ELECTRICAL POSITION

2¾ indicator

C

1 31⁄32

B

¼ fpt compressed air conn.*

2 ½

D

E

45°

A fpt

F

G

* ¼ " BSP to ¼ " fpt adapter shipped loose .

FLOW

dimensions in inches

Valve

Wt,

designation

A

B

C

D

E

F

G

lb

3 28⁄32 3 28⁄32 3 28⁄32 3 28⁄32 3 28⁄32 3 28⁄32 5 25⁄32 5 25⁄32

2 9⁄16 2 31⁄32 3 9⁄16 4 11⁄32

7 3⁄16 7 15⁄32

3 25⁄32 3 25⁄32 3 25⁄32 3 25⁄32 3 25⁄32 3 25⁄32 6 15⁄32 6 15⁄32

6 ½ 6 ¾ 6 15⁄16 7 9⁄32 7 9⁄16 7 31⁄32

1 27⁄32 1 27⁄32 1 27⁄32 1 27⁄32 1 27⁄32 1 27⁄32 2 7⁄16 2 7⁄16

2.9 3.3 3.5 4.8 5.3 6.8

1447-01 1447-0 1447-1 1447-2 1447-3 1447-4 1447-5 1447-6

½ ¾

7 7⁄8

1

8 19⁄32

1 ¼ 1 ½

4 ¾

8 ¾

5 29⁄32

9 17⁄32

2

10 27⁄32 11 11⁄32

2 ½

7 ½

– –

18.7

8 11⁄16

3

21.1

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com