Combustion Catalog | Fives North American

Sheet 4085 Page 6

EXPLOSION RESISTANT ASSEMBLY (ERA) cables are intended for use in systems that require sealed ignition wiring (Class 1 Div. 2 applications). Although the wiring method used between the ignition transformer and the spark plug was designed and chosen to be suitable for use in Class 1 Div. 2 hazardous locations, it DOES NOT carry certifications or third-party approvals. 4085-ERA cables feature sealed aircraft type ignition cable construction with flexible stainless-steel conduit, and a ¾“ - 20 threaded collar to connect to North American -ERA spark igniters. See Sheet 4055 and 4051 for -ERA Igniter details. Any of the standard 4085 transformer secondary connection types can be configured for connection to an ignition transformer mounted in an appropriate enclosure. To order a 4085-ERA cable use the part number format below. Cables can also be ordered in custom engineered lengths, contact Fives North American for details. Note: The wire used in 4085-ERA cables is slightly different than other 4085 cables. The maximum operating temperature is 482 °F (250 °C). 4085-ERA SEALED AIRCRAFT STYLE IGNITON CABLES:

1.50" (38.1)

4055-X-ERA Igniter

4055-D-ERA Igniter

4051-C-ERA Igniter

Free Length (inches)

Conduit Length (feet)

Transformer Secondary Connection

Stainless steel braided conduit with PTFE liner 3/4 " - 20 threaded connection

1.5" (38.1)

7mm Silicone cable with 16 AWG tinned copper conductor

Ceramic insulator

Spring volute (for electrical contact with spark plug)

1/2 " NPT fitting

Protective shipping plug (removed before attaching to igniter)

CONFIGURED PART NUMBER ORDERING INFORMATION

TRANSFORMER SECONDARY CONNECTION (INPUT) TYPES A = #10 Ring Tongue B = 1/4 " Ring Tongue C = Standard Straight 1/4 " post F = Female Right-angle 1/4 " blade FS = Female Straight 1/4 " blade X = No Connection

4085-ERA -

-

-

Length of Conduit in Feet (M) Standard lengths = 5 (1.5), 10 (3.0), 15 (4.5), 20 (6.0), 25 (7.6)

Ignition cable free lenght in inches (mm) Standard lengths = 6 (152), 12 (304), 18 (457), 24 (610)

Transformer Secondary Connection (Input)

4085-ERA cables are available without a secondary connection and a 24" (610 mm) free length as:

Part

Length feet (M)

Part

Length feet (M) 15 (4.5) 20 (6.0)

Part

Length feet (M) 25 (7.6) 30 (9.1)

Part

Length feet (M) 35 (10.7) 40 (12.2)

Number

Number

Number

Number

R980-1810 R980-1811

5 (1.5)

R980-1812 R980-1813

R980-1814 R980-1830

R980-1835 R980-1840

10 (3.0)

Made with FlippingBook flipbook maker