Combustion Catalog | Fives North American

Capacity | 4211 EcoFornax ™ LE

VARIANTS The GLE burner is a "pre-packaged LE" configured to fire oil field steam generators at 62.5, 85 or 100 MM Btu/h HHV. It is supplied with a pre-piped 4020 pilot, ignition cable, NEMA 4 ignition transformer; 3 pre-piped, pre-wired, pre-set, pressure switches (for purge, low combustion air, and low fire proving); and a junction box for wiring to the necessary control hard- ware, simplifying installation and field start-up.

The LEx burner is the LE without the secondary fuel injectors. It operates at excess air rates between 60-80% at a standard input ranging from 3 to 200 MM Btu/h HHV with larger sizes available (e.g. 400 MM Btu/h built for a calciner). It is intended for lower temperature applications where secondary air is normally employed to achieve process temperatures between 300-1600°F. LEx burners normally require an extended primary zone reaction chamber to protect the flame from the lower temperature secondary process stream. See Bulletin 4213 for more information.

LE Burner Capacity and Characteristics

Input at 10% XSA (million Btu/hr) 3

Main Air Flow (scfh)

Flame

LE Designation

Pilot 1

Diameter (feet) 2

Length (feet) 2

4211-4-5X1.5GG 4211-5-6X1.5GG 4211-7-8X1.5GG 4211-8-6X2GG 4211-10-7X2GG 4211-11-8X2GG 4211-15-5X3GG 4211-18-6X3GG 4211-21-7X3GG 4211-27-5X4GG 4211-33-6X4GG 4211-38-7X4GG 4211-44-8X4GG 4211-48-9X4GG 4211-54-10X4GG 4211-62-5X6GG 4211-74-6X6GG 4211-86-7X6GG 4211-98-8X6GG 4211-111-9X6GG 4211-124-10X6GG 4211-116-5X8WB 4211-140-6X8WB 4211-163-7X8WB 4211-182-5X10WB 4211-219-6X10WB 4211-256-7X10WB 4211-292-8X10WB

4.1

43,000 51,600 68,800 85,100 99,300 113,500 156,300 187,500 218,800 269,000 322,900 376,700 430,500

4020-0- LP 4020-0- LP 4020-2- LP 4020-2- LP 4020-3- LP 4020-3- LP 4020-4- LP 4020-4- LP 4020-4- LP 4020-5- LP 4020-5- LP 4020-5- LP 4020-6- LP /5 4020-6- LP /5 4020-6- LP /5 4020-6- LP /5 4020-6- LP /5 4020-7- LP /6 4020-7- LP /6 4020-7- LP /6 4020-7- LP /6 4020-7- LP /6 4020-7- LP /6 4020-7- LP /6 4020-7- LP /6 4020-7- LP /6 4020-7- LP /6 4020-7- LP /6

5.0 6.0 6.5 7.5 8.0 9.0 10.5 12.0 12.5 13.5 14.5 15.0 15.5 16.5 17.0 18.0 20.0 21.5 22.5 23.5 24.5 24.0 25.0 27.0 29.0 31.0 33.0 35.0

2.0 2.0 2.0 2.3 2.3 2.3 2.5 2.8 2.8 3.0 3.3 3.5 3.8 4.0 4.3 4.5 4.8 5.0 5.5 5.8 6.0 6.0 6.3 6.5 7.0 7.5 7.8 8.0

5.0 6.6 8.2 9.6

10.9 15.0 18.0

21.1

25.9

31.1

36.3 41.4 46.6 51.8 58.8 70.5 82.3 94.1

484,300 538,200 610,600 732,800 854,900 977,000 1,099,200 1,221,300 1,151,700 1,382,000 1,612,300 1,802,400 2,162,900 2,523,400 2,883,900

105.8 117.6 110.9 133.0 155.2 173.5 208.2 242.9 277.6

1 Recommended pilot; not included 2 Flame shape may vary based on reaction chamber length and internal profile 3 Under some conditions, firing rate may be up to 15% higher than rated input