Lowest Emissions | 4213 EcoFornax ™ LEx
— Burner Construction: robust, suitable for industrial applica- tions. Metal parts protected from radiation by ceramic exten- sions cast into burner hot face.
NOx and CO Emissions Comparison* Example at 1200º F Process Temperature
— Higher Capacities: Are available
Typical Cold Air Burner
Magna-Flame LEx System
— Application Temperature: 200 - 2400°F
NOx CO
82 20
9 5
— Sample Fuels: Natural gas, propane, land-fill gas, syngas, low Btu gases, refinery fuels, biogas, light oils. Consult Fives North American Combustion, Inc. sales and application engineering for your specific needs. — Refractory: 3000°F material, oven dried and pre-fired to 1800°F prior to shipment are available, consult Fives North American Combustion, Inc. sales and application engineering.
Emissions ppmv at 3% O 2
*Application dependent
REACTION CHAMBER OPTIONS:
XRC Reaction Chamber
HRC Reaction Chamber
SRC Reaction Chamber
• Extended length for 100% flame coverage • For process temperatures < 1400°F
• Extended length for 100% flame coverage • For use with North American 9545 Series Hot Gas Generator • Includes roller support assembly
• Shortest length • Used if flame shroud is provided by customer or if process temperatures > 1400°F
Fives North American Combustion, Inc. will review each application and advise on the appropriate reaction chamber design.
Bulletin 4213 Page 3
Made with FlippingBook flipbook maker