Combustion Catalog | Fives North American

Sample Standard Data Sheet | 8631 Venturi

Bulletin 8631 page 7

Customer/order/job number: Sizing example data sheet

Item Number: 8631-16

Date:

Standard Conditions Standard Day Flow Standard Day Flow

250000

SCFH SCFM

4167

Fluid

Dry Air 0.0763

Standard Day Density

lb/ft 3

Standard Day Temperature Standard Day Pressure

60

degrees F

14.696

psi

Actual Conditions Temperature

100

degrees F FT. amsl

Elevation

1000

Density

0.0682

lb/ft 3

Atomspheric Pressure Upstream Pressure Pressure Differential

14.146

psi

0

"w.c. "w.c.

2.361

Actual Flow Actual Flow Mass Flow

279702

ACFH SCFM lb/min

4662

327

Permanent Press Loss Reynolds Number Discharge Coefficient

0.291

"w.c.

405925

0.985

Venturi Size Venturi Inlet ID

8631-16

15.5

in in

Venturi Throat ID Venturi Beta Ratio

10.85

0.7

Pressure Permanent

% of

Output

dp

Flow Rate Flow Rate

Mass Flow

Reynolds Number

Discharge

dp

(mADC) ("w.c.)

(scfh)

(acfh)

(lb/min)

Coefficient Loss ("w.c.)

0

4

0

0 0

0 0

0.000 0.000

0 0

0 0

0.00 0.00

below min. Re number

0.33

4.0528

0.01

1% additional flow error

10

5.60

0.30

89018

99594

113.214

144539

0.98

0.04

20 30 40 50 60 70 80 90

7.20 8.80 10.40 12.00 13.60 15.20 16.80 18.40 20.00 16.592

0.60 0.90 1.20 1.50 1.80 2.10 2.40 2.70 3.00 2.361

126459 154790 178631 199599 218523 235893 252033 267165 281452 250000

141484 173180 199855 223314 244485 263920 281977 298907 314892 279702

160.870 196.909 227.239 253.912 277.985 300.082 320.614 339.864 358.038

205332 251332 290044 324090 354815 383020 409227 433797 456994 405925

0.985 0.985 0.985 0.985 0.985 0.985 0.985 0.985 0.985 0.985

0.07 0.11 0.15 0.19 0.22 0.26 0.30 0.33 0.37 0.29

100 78.7

327.161

Design point

Minimum flow: 1.5% additional flow error

0.8

4.128

0.024

24677

27609

31.392

40069

0.96

0.01

Made with FlippingBook flipbook maker