Installation | 8632 Venturi
INSTALLATION
Piping Considerations:
A certain length of straight upstream and downstream piping is necessary to optimize the accuracy of any differential pressure device.
Upstream: The following tabulation provides the minimum straight upstream lengths (expressed as multiples of pipe ID) required for 0.0% and 0.5% additional potential affect in base flow accuracy.
Reduer 2D to D
Expander 05D to D over a length of D to 2D
Full bore ball or gate valve fully open
Two or more 90° bends
over a length of 1.5D to 3D
Upstream feature
Single 90°bend
Additonal Uncertainty Length
0.00% 0.50% 0.00% 0.50% 0.00% 0.50% 0.00% 0.50% 0.00% 0.50% 28D 14D 36D 18D 14D 7D 30D 15D 20D 10D
Downstream: For zero additional uncertainty due to downstream piping, ensure that there are no fittings for 7D downstream of the Venturi or 3.5D for 0.50% additional uncertainty.
DIMENSIONS
A
¼ " NPT high pressure tap ¼ " NPT low pressure tap
C
H°
B
ØF # holes - J K bore ID
BC
D Pipe Size
M
L
E
Venturi
Designation
A
B
C
D
E
F
BC
H
J
K
L
M
Wt.
8632-6-S
13.333 4.190 13.333 4.190 15.596 4.440 15.596 4.440 20.347 4.940 20.347 4.940 24.873 5.440 24.873 5.440
5.634 5.634 6.287 6.287 7.645 7.645 8.951 8.951
3 3 4 4 6 6 8 8
7,500 7,500 9,000 9,000
0.750 0.750 0.750 0.750 0.880 0.880 0.880 0.880
6.000 6.000 7.500 7.500 9.500 9.500 11.750 11,750
45.000 4 2.148 45.000 4 2.148 22.500 8 2.818 22.500 8 2.818 22.500 8 4.246 22.500 8 4.246 22.500 8 5.587 22.500 8 5.587
0.940 6.080 0.940 6.080 0.940 6.580 0.940 5.580 1.000 7.580 1.000 7.580 1.130 8.580 1.130 8.580
33.481 33.481 50.444 50.444 93.352 93.352 166.745 166.745
8632-6-S316L
8632-7-S
8632-7-S316L
8632-8-S
11,000 11,000 13,500 13.500
8632-8-S316L
8632-9-S
8632-9-S316L
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .
Bulletin 8632 page 6