8695 ORIFICE PLATE Data Sheet
Feb 2009
Customer Name: Customer Number: Customer P.O.: Order Item:
Shop Order: Line Item Number: Quantity:
1
8695-6-SST;
Order Date: Schedule Date:
Calculation Number:
Fluid Data Fluid Type:
Pipe Data Pipe size:
Natural Gas
3"
Specific Gravity:
0.6
Schedule:
40
Fluid Temperature:
60 F
Pipe O.D.
3.5"
Flow Rate:
15000 scfh
Pipe I.D.
3.068"
Line Pressure:
3 psi
Pipe Wall Thickness:
0.216"
Atmos. Pressure:
17.038 psi
Pipe Description:
Absolute Pressure:
17.038 psi
Flange Data Flange Type:
Elevation:
1200 ft.
8763B-6
Differential Pressure:
10 inH2O
Tap Type:
flange
Orifice Bore Diameter:
1.985"
Bolt Circle:
6.63"
Beta ratio:
0.647
Avg. Press. Recovery:
41.64 %
No. of Bolts:
8
Perm. Press. Loss:
58.362 %
Bolt Diameter:
0.75"
3" ANSI Class 300 forged steel threaded orifice flange assembly with 2-1/16" gaskets, bolts, nuts and jack bolts for orifice plate (1/2" NPT threaded flange taps)
Unrecoverable Loss:
5.836 inH2O
Advanced Fluid Properties Density:
Flange Description:
0.0534 lb/ft^3
Standard Density:
0.0461 lb/ft^3
Normal Density: Actual Volume Flow:
12937.83 ft^3/hr
Mass Flow:
11.519 lbs/min
ISO 5167-1 2003 Measurement of Fluid Flow and ISO 5167-2 Orifice Plates applicable for 2” through 38” sizes, and ASME MFC-14M-1995 Measurement of Fluid Flow Using Small Bore Orifice Meters for 1/4” through 1- 1/2” nominal line sizes are used for flow rate a nd orifice bore computations. The standards used are applicable to orifice plates used with flange pressure tappings, corner pressure tappings, or with D and D /2 pressure tappings (D and D/2 pressure tappings [upstream tap =one pipe diameter from face, downstreamtap = 1/2 diameter from face] are not applicable to small bore orifices i.e. 1-1/2" pipe size and smaller). Orifice plates with vena contracta pressure tappings are not considered or used in these standards.
Viscosity:
2.2791E-07 lb*sec/ft^2
Isentropic Exponent:
1.297
Molecular Weight:
17.503158
Discharge Coefficient:
0.612
Reynolds Number:
130391.87296
WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc.,areinherent with any combustion application. Parts of this product may exceed 160F in operation and present a contact hazard. Fives North American Combustion, Inc. urges compliance with National Safety Standards and insurance Underwriters recommendations, and care in operation.