Combustion Catalog | Fives North American

Capacities | 4384 Fuel Directed

CONTROL

COMBUSTION AIR CAPACITIES, scfh long flame mode Capacities are reduced up to 10% in short flame mode. Burner designation 0.06"w.c.* 3"w.c. 6"w.c. † 4384-8 4 070 28 600 40 700 4384-9 7 100 50 800 71 500 4384-10-A 8 900 63 000 89 200 4384-10-B 11 300 80 000 113 000 4384-12 16 000 114 000 160 000 4384-14 20 000 142 000 200 000 4384-16 26 000 187 000 264 000 4384-18 33 000 238 000 337 000 4384-20 42 000 296 000 419 000 4384-22 51 000 361 000 509 000 4384-24 61 000 430 000 608 000 4384-26 75 000 530 000 750 000 * min. air rate † recommended press. (See "Operation".) air pressure

Mass flow control is recommended. Standard 4384 Fuel Directed® Burners have a single gas connection with internal radial/forward gas adjustment for flame shaping. Main and center jet gas should be supplied to the burner at the same time. See flow control schematic. PILOT and FLAME SUPERVISION Burners are ignited with a gas-boosted pilot. Pilot air pressure must be at least 10"w.c., and pilot regulator must be cross- connected to the pilot air line (see Sheet 4014). If flame supervision is used, pilot must be of the interrupted type. UV flame detection is recommended (using an 883_-D adapter). It is possible for a UV scanner mounted on this burner to sight flame(s) of other burners in the same firing chamber. Consult Fives North American Combustion, Inc. for configuration guidiance on multiple burner applications. LOW NOx The 4384 Fuel Directed Burner is an inherently Low NOx burner. In conjunction with other NOx reducing features, it is capable of meeting emission limitations for new or retrofit applications in environmentally sensitive installations. Contact your Fives North American Combustion, Inc. Sales Engineer for specific applications. BURNER TILE CONSTRUCTION 4384 Burners do not include a tile. Tunnel shapes and recom- mended installation is shown on Dimensions & Installation 4384. OTHER FUELS

RANGE OF FLAME LENGTHS and DIAMETERS (2000 F Furnace) in feet with 8 or 2 psig gas Air/gas ratio set for 10% excess air.

SHORT FLAME (10% reduced capacity) air pressure

LONG FLAME (full capacity) air pressure

FLAME DIA. (full capacity) long or short

Burner designation

3"w.c. 6"w.c. 3"w.c. 6"w.c.

4384-8 4384-9

3

4

8 9

14 15 16 18

2 2

3 ½ 3 ½ 4 ½

4 ½

4384-10-A 4384-10-B 4384-12 4384-14 4384-16 4384-18 4384-20 4384-22 4384-24 4384-26

5 6 7 8

10 12 14 15

2.5 2.5 2.5

5

20 24 30 34 40 45 50 60

5 ½

3 3

7

10 12 15 18 20 24

20 25 30 32 40 49

8 ½

3.5 3.5

10 ½

13 15 19

4 4

4.5 ‡ Flame lengths will be longer in a lower temperature furnace.

For other gaseous fuels and oils, contact your Fives North American Combustion, Inc. Sales Engineer.

Bulletin 4384 Page 3