Combustion Catalog | Fives North American

Part Numbers | 4422 Fire•All™

Bulletin 4422 Page 6

Example 4422 Catalog Numbers examples are given from smallest to largest available burner sizes

Standard Burner 4422-2-BO

through 4422-8-ABO through 4422-8-A

burner only

4422-2

burner complete w/9" tile

Standard Burner With Tile Jacket 4422-2-LC

through 4422-8-ALC through 4422-8-AL4 through 4422-8-AL9

burner complete w/9" tile and steel jacket burner complete w/9" tile and 304 SST jacket burner complete w/9" tile and 309 SST jacket

4422-2-L4 4422-2-L9

Burner With Double-Boss Body 4422D-2-BO through 4422D-6-BBO burner only w/double-boss body 4422D-2 through 4422D-6-B

burner complete w/9" tile and double boss body

4422D-2-LC through 4422D-6-BLC 4422D-2-L4 through 4422D-6-BL4 4422D-2-L9 through 4422D-6-BL9

burner complete w/9" tile, double-boss body and steel jacket burner complete w/9" tile, double-boss body and 304 SST jacket burner complete w/9" tile, double-boss body and 309 SST jacket

Burner With Hinged Burner Body 4422HR-2-BO through 4422HR-8-ABO burner only w/right-hand hinged body when main air is at 12 o'clock 4422HL-2-BO through 4422HL-8-ABO burner only w/left-hand hinged body when main air is at 12 o'clock 4422HR-2 through 4422HR-8-A burner complete w/9" tile and left-hand hinged body when main air is at 12 o'clock 4422HR-2-LC through 4422HR-8-ALC burner complete w/9" tile and steel jacket with right-hand hinged body when main air is at 12 o'clock 4422HL-2-LC through 4422HL-8-ALC burner complete w/9" tile and steel jacket with left-hand hinged body when main air is at 12 o'clock 4422HR-2-L4 through 4422HR-8-AL4 burner complete w/9" tile and 304 SST jacket wth right-hand hinged body when main air is at 12 o'clock 4422HL-2-L4 through 4422HL-8-AL4 burner complete w/9" tile and 304 SST jacket with left-hand hinged body when main air is at 12 o'clock 4422HR-2-L9 through 4422HR-2-AL9 burner complete w/9" tile and 309 SST jacket with right-hand hinged body when main air is at 12 o'clock 4422HL-2-L9 through 4422HL-2-AL9 burner complete w/9" tile and 309 SST jacket with left-hand hinged body when main air is at 12 o'clock Fiber Wall Mounting Burners 4422-2-Z through 4422-8-AZ burner complete w/"Z" dimension (2" to 9" round) 4422D-2-Z through 4422D-6-BZ burner complete w/double-boss body and "Z" dimension (2" to 9" round) Flangeless Burners 4422-2-FM through 4422-8-AFM burner complete w/9" tile and flangeless mounting 4422D-2-FM through 4422D-6-BFM burner complete w/9" tile, double-boss body and flangeless mounting burner complete w/9" tile and right-hand hinged body when main air is at 12 o'clock 4422HL-2 through 4422HL-8-A WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com