North American 4422 Nozzle-Mix Gas Burners

Dimensions & Parts List 4422-2

STANDARD SERIES

4422-2-BO THROUGH -8-ABO BURNER ONLY 4422-2 THROUGH -8-A BURNER COMPLETE W/9" TILE 4422-2-LC THROUGH -8-ALC BURNER COMPLETE W/9" TILE and STEEL JACKET 4422-2-L4 THROUGH -8-AL4 BURNER COMPLETE W/9" TILE and 304 SST JACKET 4422-2-L9 THROUGH -8-AL9 BURNER COMPLETE W/9" TILE and 309 SST JACKET

F

DIMENSIONS inches

¾ fpt – 3 holes for flame detector, Observation Port and Pilot Tip 

M

45°

Observation Port

 tap

D 

C 

E

H

9

45°

¾ " wide slots

M

Q – Bolt Circle R – (8) bolts

G

3 19⁄32 rad.

B – fpt Gas Conn. 

1⁄8 "

Optional Steel Jacket

A – fpt Air Conn. 

M

J

1⁄8 " Flange Air Pressure Tap (all sizes)

K

N

L

P

Flower pot air connection for -8-A only 

G

A

Burner designation

C  D  E F

A

B 1 1

G

H

J

K L

M

N

P

Q

R

wt, lb

4422-2 4422-3 4422-4 4422-5 4422-6

9 ½ 9 ½ 9 ½ 9 ½ 9 ½ 9 ½ 11 11 11

8 ½ 8 ½ 8 ½ 8 ½ 8 ½ 8 ½ 10 10 10

5 ½ 5 ½ 5 ½ 5 ½ 5 ½ 5 ½ 7 9⁄16 7 9⁄16 7 9⁄16

5 ¼ 5 ¼ 5 ¼ 5 ¼

2 2 2 2 2 2

43⁄8 43⁄8 43⁄8 43⁄8 43⁄8 43⁄8

83⁄8

105⁄8

5 ¼ 5 ¼ 5 ¼ 5 ¼ 5 ¼ 5 ¼ 61⁄8 61⁄8 61⁄8

6 6 6 6 6 6

12 12 12 12 12 12

7 ½ 7 ½ 7 ½ 7 ½ 7 ½ 7 ½ 93⁄8 93⁄8 93⁄8

3⁄8 3⁄8 3⁄8 3⁄8 3⁄8 3⁄8 ½ ½ ½

75 75 75 75 75 75

1 ¼ 1 ½

83⁄8 105⁄8 83⁄8 105⁄8 83⁄8 105⁄8 83⁄8 105⁄8 83⁄8 105⁄8

2

1 ¼ 1 ½ 1 ½ 1 ½ 2 ½ 2 ½ 2 ½

2 ½

3 3 4 4 6

59⁄16 59⁄16 615⁄16 615⁄16

4422-6-B 4422-7-A 4422-7-B 4422-8-A 

25⁄8 57⁄8 25⁄8 57⁄8 25⁄8 57⁄8

11 11 11

147⁄8 147⁄8 147⁄8

6¾ 13½ 6¾ 13½ 6¾ 13½

130 130 140

1011⁄16

 Furnace opening should be ½ " larger than dimension C or D to allow for fillets and draft on mounting plate.  C dimension used for jacketed tiles only.  ¼ " body air pressure tap on -2, -3, -4, -5, -6, and 6-B. 1⁄8 " body air pressure tap on -7-A, -7-B and 8-A  "Flower Pot" type flange for -8-A. Note larger G dimension  For 4422-8-A, air and gas connections cannot be piped on the same plane. Flower pot type air connection flange would interfere with the 2 ½ " gas line.  Pilot, Flame Detector, and Observation Port positions are interchangeable as long as Pilot and Flame Detector are in adjacent holes. ¾ " pipe plug furnished for use if no Pilot.

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.