North American 4422 Nozzle-Mix Gas Burners "FM" Flangeless Mounting Series

Dimensions & Parts List 4422-4

"FM" FLANGELESS MOUNTING SERIES

4422-2-FM 4422D-2-FM

THROUGH THROUGH

-8-AFM BURNER COMPLETE W/9" TILE and FLANGELESS MOUNTING

-6-BFM BURNER COMPLETE W/9" TILE, DOUBLE-BOSS BODY and FLANGELESS MOUNTING

DIMENSIONS inches

Double-Boss Body 

¾ fpt – 3 holes for flame detector, Observation Port and Pilot Tip 

45°

Observation Port

tap 

D 

E

H

45°

M

Q – Bolt Circle R – (8) bolts

G

3 19⁄32 rad.

B – fpt Gas Conn. 

95⁄8

A – fpt Air Conn. 

M

J

1⁄8 " Flange Air Pressure Tap (all sizes)

K

P

L

Flower pot air connection for -8-A only 

G

A

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.

dimensions in inches

Burner designation 4422-2-FM 4422-3-FM 4422-4-FM 4422-5-FM 4422-6-FM 4422-6-BFM 4422-7-AFM 4422-7-BFM 4422-8-AFM 

D 

A

B

E 5 5 5 5 5 5 7 7 7

G

H

J

K

L

M

P

Q

R

wt, lb

1 ¼ 1 ½

8 ½ 8 ½ 8 ½ 8 ½ 8 ½ 8 ½

5 ¼ 5 ¼ 5 ¼ 5 ¼

10 ¼ 10 ¼ 10 ¼ 10 ¼ 10 ¼ 10 ¼ 13 ½ 13 ½ 13 ½

4 ¼ 4 ¼ 4 ¼ 4 ¼ 4 ¼ 4 ¼

8 ½ 8 ½ 8 ½ 8 ½ 8 ½ 8 ½

7 ½ 7 ½ 7 ½ 7 ½ 7 ½ 7 ½ 93⁄8 93⁄8 93⁄8

1 1

2 2 2 2 2 2

37⁄8 37⁄8 37⁄8 37⁄8 37⁄8 37⁄8 5 ¼ 5 ¼ 5 ¼

77⁄8 77⁄8 77⁄8 77⁄8 77⁄8 77⁄8

3⁄8 3⁄8 3⁄8 3⁄8 3⁄8 3⁄8 ½ ½ ½

75 75 75 75 75 75

1 ¼ 1 ½ 1 ½ 1 ½ 2 ½ 2 ½ 2 ½

2

2 ½

3 3 4 4 6

59⁄16 59⁄16 615⁄16 615⁄16

10 10 10

25⁄8 25⁄8 25⁄8

103⁄8 103⁄8 103⁄8

5 5 5

10 10 10

130 130 140

1011⁄16

 Furnace opening should be ½ " larger than dimension D to allow for fillets and draft on mounting box.  Double-Boss bodies through -6-B sizes only. Pilot and flame supervisory connections are ¾ fpt on 45° and 90° angles as shown. See Dimensions and Parts List 4422-5 for double-boss burners with mounting flanges.  ¼ " body air pressure tap on -2, -3, -4, -5, -6, and 6-B. 1⁄8 " body air pressure tap on -7-A, -7-B and 8-A  "Flower Pot" type flange for -8-A. Note larger G dimension  For 4422-8-A, air and gas connections cannot be piped on the same plane. Flower pot type air connection flange would interfere with the 2 ½ " gas line.  Pilot, Flame Detector, and Observation Port positions are interchangeable as long as Pilot and Flame Detector are in adjacent holes. ¾ " pipe plug furnished for use if no Pilot.