Combustion Catalog | Fives North American

North American 4422 Nozzle-Mix Gas Burners "HL" and "HR" Hinged Series

Dimensions & Parts List 4422-6

"HL" AND "HR" HINGED SERIES

4422HL AND HR-2-BO 4422HL AND HR-2 4422HL AND HR-2-LC 4422HL AND HR-2-L4 4422HL AND HR-2-L9

THROUGH THROUGH THROUGH THROUGH THROUGH

-8-ABO HINGED BURNER ONLY

-8-A

HINGED BURNER COMPLETE W/9" TILE

-8-ALC HINGED BURNER COMPLETE W/9" TILE and STEEL JACKET -8-AL4 HINGED BURNER COMPLETE W/9" TILE and 304 SST JACKET -8-AL9 HINGED BURNER COMPLETE W/9" TILE and 309 SST JACKET

Note: HR (Hinged-Right) model shown below.

DIMENSIONS inches

A

G

Flower pot air connection for -8-A only 

K

B –fpt Gas conn. 

J

9

Wing Nut location 4422-7-A, -7-B, and -8-A only

F

A –fpt Air conn. 

1⁄8 Flange Air Pressure Tap (all sizes)

N

G

M

tap 

H

22 ½ °

D 

45°

E

45°

22 ½ °

¾ " wide slots (4)

C 

Observation Port

3 19⁄32 rad.

1⁄8 "

Optional Steel Jacket

from face of Mounting Flange to C of Hinge Pins L

T

U

M

M

N

N

¾ fpt – 3 holes for flame detector, Observation Port and Pilot Tip 

P

L

Wing Nut location 4422-2 thru -6-B only

Burner

dimensions in inches

D 

C 

designation

A

B

E F

G

H

J

K

L

M

N

P

T

U wt, lb

4422HL & HR-2 4422HL & HR-3 4422HL & HR-4 4422HL & HR-5 4422HL & HR-6 4422HL & HR-6-B 4422HL & HR-7-A 4422HL & HR-7-B 4422HL & HR-8-A 

1 ¼ 1 ½

1 1

9 ½ 9 ½ 9 ½ 9 ½ 9 ½ 9 ½

8 ½ 8 ½ 8 ½ 8 ½ 8 ½ 8 ½

5 5 5 5 5 5 7 7 7

½ ½ ½ ½ ½ ½

5 ¼ 5 ¼ 5 ¼ 5 ¼

2 2 2 2 2 2

43⁄8 43⁄8 43⁄8 43⁄8 43⁄8 43⁄8 57⁄8 57⁄8 57⁄8

83⁄8 83⁄8 83⁄8 83⁄8 83⁄8 83⁄8

105⁄8 105⁄8 105⁄8 105⁄8 105⁄8 105⁄8 141⁄16 141⁄16 141⁄16

5 ¼ 5 ¼ 5 ¼ 5 ¼ 5 ¼ 5 ¼ 61⁄8 61⁄8 61⁄8

6 6 6 6 6 6

12 12 12 12 12 12

43⁄8 43⁄8 43⁄8 43⁄8 43⁄8 43⁄8 5 ½ 5 ½ 5 ½

2 2 2 2 2 2

75 75 75 75 75 75

2

1 ¼ 1 ½ 1 ½ 1 ½ 2 ½ 2 ½ 2 ½

2 ½

3 3 4 4 6

59⁄16 59⁄16 615⁄16 615⁄16

11 11 11

10 10 10

9⁄16 9⁄16 9⁄16

25⁄8 25⁄8 25⁄8

11 11 11

6 ¾ 6 ¾ 6 ¾

13 ½ 13 ½ 13 ½

21⁄8 21⁄8 21⁄8

130 130 140

1011⁄16

 Furnace opening should be ½ " larger than dimension C or D to allow for fillets and draft on mounting plate.  C dimension used for jacketed tiles only.  ¼ " body air pressure tap on -2, -3, -4, -5, -6, and 6-B. 1⁄8 " body air pressure tap on -7-A, -7-B and 8-A  "Flower Pot" type flange for -8-A. Note larger G dimension  For 4422-8-A, air and gas connections cannot be piped on the same plane. Flower pot type air connection flange would interfere with the 2 ½ " gas line.  Pilot, Flame Detector, and Observation Port positions are interchangeable as long as Pilot and Flame Detector are in adjacent holes. ¾ " pipe plug furnished for use if no Pilot.

Made with FlippingBook flipbook maker