North American 4422 Nozzle-Mix Gas Burners "HL" and "HR" Hinged Series
Dimensions & Parts List 4422-6
"HL" AND "HR" HINGED SERIES
4422HL AND HR-2-BO 4422HL AND HR-2 4422HL AND HR-2-LC 4422HL AND HR-2-L4 4422HL AND HR-2-L9
THROUGH THROUGH THROUGH THROUGH THROUGH
-8-ABO HINGED BURNER ONLY
-8-A
HINGED BURNER COMPLETE W/9" TILE
-8-ALC HINGED BURNER COMPLETE W/9" TILE and STEEL JACKET -8-AL4 HINGED BURNER COMPLETE W/9" TILE and 304 SST JACKET -8-AL9 HINGED BURNER COMPLETE W/9" TILE and 309 SST JACKET
Note: HR (Hinged-Right) model shown below.
DIMENSIONS inches
A
G
Flower pot air connection for -8-A only
K
B –fpt Gas conn.
J
9
Wing Nut location 4422-7-A, -7-B, and -8-A only
F
A –fpt Air conn.
1⁄8 Flange Air Pressure Tap (all sizes)
N
G
M
tap
H
22 ½ °
D
45°
E
45°
22 ½ °
¾ " wide slots (4)
C
Observation Port
3 19⁄32 rad.
1⁄8 "
Optional Steel Jacket
from face of Mounting Flange to C of Hinge Pins L
T
U
M
M
N
N
¾ fpt – 3 holes for flame detector, Observation Port and Pilot Tip
P
L
Wing Nut location 4422-2 thru -6-B only
Burner
dimensions in inches
D
C
designation
A
B
E F
G
H
J
K
L
M
N
P
T
U wt, lb
4422HL & HR-2 4422HL & HR-3 4422HL & HR-4 4422HL & HR-5 4422HL & HR-6 4422HL & HR-6-B 4422HL & HR-7-A 4422HL & HR-7-B 4422HL & HR-8-A
1 ¼ 1 ½
1 1
9 ½ 9 ½ 9 ½ 9 ½ 9 ½ 9 ½
8 ½ 8 ½ 8 ½ 8 ½ 8 ½ 8 ½
5 5 5 5 5 5 7 7 7
½ ½ ½ ½ ½ ½
5 ¼ 5 ¼ 5 ¼ 5 ¼
2 2 2 2 2 2
43⁄8 43⁄8 43⁄8 43⁄8 43⁄8 43⁄8 57⁄8 57⁄8 57⁄8
83⁄8 83⁄8 83⁄8 83⁄8 83⁄8 83⁄8
105⁄8 105⁄8 105⁄8 105⁄8 105⁄8 105⁄8 141⁄16 141⁄16 141⁄16
5 ¼ 5 ¼ 5 ¼ 5 ¼ 5 ¼ 5 ¼ 61⁄8 61⁄8 61⁄8
6 6 6 6 6 6
12 12 12 12 12 12
43⁄8 43⁄8 43⁄8 43⁄8 43⁄8 43⁄8 5 ½ 5 ½ 5 ½
2 2 2 2 2 2
75 75 75 75 75 75
2
1 ¼ 1 ½ 1 ½ 1 ½ 2 ½ 2 ½ 2 ½
2 ½
3 3 4 4 6
59⁄16 59⁄16 615⁄16 615⁄16
11 11 11
10 10 10
9⁄16 9⁄16 9⁄16
25⁄8 25⁄8 25⁄8
11 11 11
6 ¾ 6 ¾ 6 ¾
13 ½ 13 ½ 13 ½
21⁄8 21⁄8 21⁄8
130 130 140
1011⁄16
Furnace opening should be ½ " larger than dimension C or D to allow for fillets and draft on mounting plate. C dimension used for jacketed tiles only. ¼ " body air pressure tap on -2, -3, -4, -5, -6, and 6-B. 1⁄8 " body air pressure tap on -7-A, -7-B and 8-A "Flower Pot" type flange for -8-A. Note larger G dimension For 4422-8-A, air and gas connections cannot be piped on the same plane. Flower pot type air connection flange would interfere with the 2 ½ " gas line. Pilot, Flame Detector, and Observation Port positions are interchangeable as long as Pilot and Flame Detector are in adjacent holes. ¾ " pipe plug furnished for use if no Pilot.