Dimensions & Parts List 4422-7 Page 2
"Z-DIMENSION" GAS BURNER PARTS LIST
round Mounting and Tile assembly (thin wall) Z (dim. varies)
Mounting
Furnace wall
Ceramic fiber modules
Studs, Gas Conn. (4)
¾ " Pipe Plug
Stud Hex Nuts (4)
Body
Mounting
Backplate
Air Tubes (8)
Backplate Gasket
Gas Tube
This construction for -7-A, -7-B, -8-A only
Gas Tube Extension (4422-8-A only)
Observation Port (8790-0)
Burner Tile
Tile Liner
Gas Connection Gasket
Fiber Blanket Insulation
Gas Connection
Burner Tile
Main Air Flange Gasket
Hex Head Cap Screws (4) 5⁄16 -18 NC 4422-2 thru -6-B 3⁄8 -16 NC 4422-7-A, -7-B, -8-A
Mounting Nuts (8) Flat Washers (8)
NOTE: See Supplement DF-M2 for more detailed installation recommendations for Fiber-Lined Furnaces.
Hex Nuts (4) 5⁄16 -18 NC 4422-2 thru -6-B 3⁄8 -16 NC 4422-7-A, -7-B, -8-A
PARTS for 4422 "Z-Dim." Fiber-wall mounting Burners
Part name
4422-2-Z 4422-3-Z 4422-4-Z 4422-5-Z 4422-6-Z 4422-6-BZ 4422-7-AZ 4422-7-BZ 4422-8-AZ
Burner Only (assembly)
4422-2- BO 3-2466-9
4422-3- BO 3-2466-9
4422-4- BO 3-2466-9
4422-5- BO 3-2466-9
4422-6- BO
4422-6- BBO
4422-7- ABO 4422-7- BBO
4422-8- ABO
Body
3-2466-10 3-2466-10
3-3267-3
3-3267-3
3-3267-4
Double-Boss ** Burner Only (assembly) Double-Boss Body Gas Connection Assy.
4422D-2-BO 4422D-3-BO 4422D-4-BO 4422D-5-BO 4422D-6-BO 4422D-6-BBO
—
—
—
OC3-2042-2
OC3-2042-1
—
—
—
4-8620-1 3-2465-4 3-2468-2
4-8620-1 3-2465-4 3-2468-2
4-8620-2 3-2465-5 3-2468-2
4-8620-3 3-2465-6 3-2468-2
4-8620-3 4-8620-3 3-2465-6 3-2465-6 3-2468-2 3-2468-2
4-8620-4 4-8620-4
4-8620-5 4-6126-1
Gas Connection
3-3268-2
3-3268-2
Gas Tube
†
†
†
Gas Tube Ext.
—
—
—
—
—
—
—
—
4-6121-1 3-3269-2 3-3272-1 3-3325-1 R510-2259 3-3272-1 4-3684-2 8765-8x7-D
Backplate
4-2459-2 3-2607-1 3-2584-1 R510-2219 3-2473-1 3-3643-1‡ 3-2544-2 4-5371-2
4-2459-2 3-2607-1 3-2584-1 R510-2219 3-2473-1
4-2459-2 3-2607-1 3-2584-1 R510-2219 3-2473-1
4-2459-2 3-2607-1 3-2584-1
4-2459-2 3-2607-1 3-2584-1
4-2459-2 3-2607-1 3-2584-1
3-3269-2 3-3272-1 3-3325-1
3-3269-2 3-3272-1 3-3325-1
Backplate Gasket Studs, Gas Conn. (4) Stud Hex Nuts (4)
R510-2219 R510-2219 R510-2219
R510-2259 R510-2259
Gas Conn. Gasket
3-2473-1 3-3639-2 4-1695-3 4-5371-2
3-2473-1 3-3554-2 4-1695-9 4-5371-2
3-2473-1 3-5042-1 4-1695-9 4-5371-2
3-3272-1 3-3273-3 4-1695-5 4-5371-3
3-3272-1 3-3273-4 4-1695-5 4-5371-3
Air Tubes (8)
3-3643-2‡ 3-3640-2
Main Air Flange
3-2544-1 4-5371-2
4-1695-2 4-5371-2
Main Air Flange Gasket Hex Head Cap Screws (4) Hex Nuts (4) Tile Retaining Nuts
4-5371-3
R066-2670 R510-2219
R066-2950 R510-2259
R510-2219
R510-2259 R970-7300-C
R066-2950 R970-7370-C
Mounting Nuts (8) Flat Washers (8) " Z" DIM Mounting & Tile Assemblies Standard
For Fiber-Wall Mounting Burners complete, with Z-dimension specified on order from 2" to 9" in 1 /
2 " increments
Mounting & Tile Assy.*
3-6322-1/X.X 3-6321-1/X.X
3-6322-2/X.X 3-6321-2/X.X
Mounting
Tile and Liner
3-6320-1
3-6320-2
For Fiber-Wall Mounting Double-Boss Burners complete, with Z-dimension specified on order from 2" to 9" in 1 /
2 " increments.
D Series
Mounting & Tile Assy.*
3-6322-3/X.X 3-6321-3/X.X
— — —
— — —
— —
Mounting
Tile and Liner — * Includes complete mounting, tile, and retainer assembly. Mounting and tile assembly part numbers have been revised to include the required "Z" dimension. When ordering tile and mounting assembly separately, include the "X.X" suffix to represent the required "Z" dimension in .5" increments, 2" min to 9" max. For example: 3-6322-1/5.5 represents tile and mounting assembly for 4422-2-Z through 4422-6-BZ burner with "Z" dimension of 5.5". ** Double Pilot and Flame Supervisory connections. †Gas tube is cast with Gas Connection for -7-A, -7-B, and -8-A sizes. ‡Includes 3-3638-1 adapter. 3-6320-7
CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237
Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com
Made with FlippingBook flipbook maker