Combustion Catalog | Fives North American

Dimensions & Parts List 4422-7 Page 2

"Z-DIMENSION" GAS BURNER PARTS LIST

round Mounting and Tile assembly (thin wall) Z (dim. varies)

Mounting

Furnace wall

Ceramic fiber modules

Studs, Gas Conn. (4)

¾ " Pipe Plug

Stud Hex Nuts (4)

Body

Mounting

Backplate

Air Tubes (8)

Backplate Gasket

Gas Tube

This construction for -7-A, -7-B, -8-A only

Gas Tube Extension (4422-8-A only)

Observation Port (8790-0)

Burner Tile

Tile Liner

Gas Connection Gasket

Fiber Blanket Insulation

Gas Connection

Burner Tile

Main Air Flange Gasket

Hex Head Cap Screws (4) 5⁄16 -18 NC 4422-2 thru -6-B 3⁄8 -16 NC 4422-7-A, -7-B, -8-A

Mounting Nuts (8) Flat Washers (8)

NOTE: See Supplement DF-M2 for more detailed installation recommendations for Fiber-Lined Furnaces.

Hex Nuts (4) 5⁄16 -18 NC 4422-2 thru -6-B 3⁄8 -16 NC 4422-7-A, -7-B, -8-A

PARTS for 4422 "Z-Dim." Fiber-wall mounting Burners

Part name

4422-2-Z 4422-3-Z 4422-4-Z 4422-5-Z 4422-6-Z 4422-6-BZ 4422-7-AZ 4422-7-BZ 4422-8-AZ

Burner Only (assembly)

4422-2- BO 3-2466-9

4422-3- BO 3-2466-9

4422-4- BO 3-2466-9

4422-5- BO 3-2466-9

4422-6- BO

4422-6- BBO

4422-7- ABO 4422-7- BBO

4422-8- ABO

Body

3-2466-10 3-2466-10

3-3267-3

3-3267-3

3-3267-4

Double-Boss ** Burner Only (assembly) Double-Boss Body Gas Connection Assy.

4422D-2-BO 4422D-3-BO 4422D-4-BO 4422D-5-BO 4422D-6-BO 4422D-6-BBO

OC3-2042-2

OC3-2042-1

4-8620-1 3-2465-4 3-2468-2

4-8620-1 3-2465-4 3-2468-2

4-8620-2 3-2465-5 3-2468-2

4-8620-3 3-2465-6 3-2468-2

4-8620-3 4-8620-3 3-2465-6 3-2465-6 3-2468-2 3-2468-2

4-8620-4 4-8620-4

4-8620-5 4-6126-1

Gas Connection

3-3268-2

3-3268-2

Gas Tube

Gas Tube Ext.

4-6121-1 3-3269-2 3-3272-1 3-3325-1 R510-2259 3-3272-1 4-3684-2 8765-8x7-D

Backplate

4-2459-2 3-2607-1 3-2584-1 R510-2219 3-2473-1 3-3643-1‡ 3-2544-2 4-5371-2

4-2459-2 3-2607-1 3-2584-1 R510-2219 3-2473-1

4-2459-2 3-2607-1 3-2584-1 R510-2219 3-2473-1

4-2459-2 3-2607-1 3-2584-1

4-2459-2 3-2607-1 3-2584-1

4-2459-2 3-2607-1 3-2584-1

3-3269-2 3-3272-1 3-3325-1

3-3269-2 3-3272-1 3-3325-1

Backplate Gasket Studs, Gas Conn. (4) Stud Hex Nuts (4)

R510-2219 R510-2219 R510-2219

R510-2259 R510-2259

Gas Conn. Gasket

3-2473-1 3-3639-2 4-1695-3 4-5371-2

3-2473-1 3-3554-2 4-1695-9 4-5371-2

3-2473-1 3-5042-1 4-1695-9 4-5371-2

3-3272-1 3-3273-3 4-1695-5 4-5371-3

3-3272-1 3-3273-4 4-1695-5 4-5371-3

Air Tubes (8)

3-3643-2‡ 3-3640-2

Main Air Flange

3-2544-1 4-5371-2

4-1695-2 4-5371-2

Main Air Flange Gasket Hex Head Cap Screws (4) Hex Nuts (4) Tile Retaining Nuts

4-5371-3

R066-2670 R510-2219

R066-2950 R510-2259

R510-2219

R510-2259 R970-7300-C

R066-2950 R970-7370-C

Mounting Nuts (8) Flat Washers (8) " Z" DIM Mounting & Tile Assemblies Standard

For Fiber-Wall Mounting Burners complete, with Z-dimension specified on order from 2" to 9" in 1 /

2 " increments

Mounting & Tile Assy.*

3-6322-1/X.X 3-6321-1/X.X

3-6322-2/X.X 3-6321-2/X.X

Mounting

Tile and Liner

3-6320-1

3-6320-2

For Fiber-Wall Mounting Double-Boss Burners complete, with Z-dimension specified on order from 2" to 9" in 1 /

2 " increments.

D Series

Mounting & Tile Assy.*

3-6322-3/X.X 3-6321-3/X.X

— — —

— — —

— —

Mounting

Tile and Liner — * Includes complete mounting, tile, and retainer assembly. Mounting and tile assembly part numbers have been revised to include the required "Z" dimension. When ordering tile and mounting assembly separately, include the "X.X" suffix to represent the required "Z" dimension in .5" increments, 2" min to 9" max. For example: 3-6322-1/5.5 represents tile and mounting assembly for 4422-2-Z through 4422-6-BZ burner with "Z" dimension of 5.5". ** Double Pilot and Flame Supervisory connections. †Gas tube is cast with Gas Connection for -7-A, -7-B, and -8-A sizes. ‡Includes 3-3638-1 adapter. 3-6320-7

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com

Made with FlippingBook flipbook maker