Combustion Catalog | Fives North American

Dimensions | 4425 Fire•All™

3 19⁄32 " rad.

See Warning •

45°

1 1⁄8 "

Section Y-Y thru Pilot or Flame Rod opening.

E

Insulating refractory

¾ " NPT – 3 holes for Flame Detector, Observation Port, and Pilot Tip. † ¾ " pipe plug furnished for use if no Pilot. § Observation Port

7 ½ " BC for -3, -4, -5 & -6 8 - 3⁄8 " bolts

Y

45°

P

Y

See ‡

Y

Y

C dia.

G

D * sq.

¾ " wide slotted holes

P

3 19⁄32 " rad.

9 3⁄8 " BC for 7-A, 7-B and 8-A 8 - ½ " bolts

F

4425- -MB Milk Bottle shaped hole T –dia.

Inconel Air Tubes

A pipe size combustion air inlet 

B pipe size gas inlet

P

P

J

9" for 4425 13 ½ " for 4425- -MB 

R

R

K

S sq.

N

NOTE: For 4425-8-A, the air and gas connections cannot be piped in the same plane, as shown on other side, because the "flower pot" type air connection flange would interfere with the 2 ½ " gas line.

dimensions in inches

Burner

Wt, Recommended

designation A

B C D

E

F

G J

K

N

P

R

S T

lb

Pilot Set

4425-2 4425-3 4425-4 4425-5 4425-6

1 ¼ 1 ½

1 1

5 5 5 5 5 5

8 ½ 8 ½ 8 ½ 8 ½ 8 ½ 8 ½

5 ¼ 5 ¼ 5 ¼ 5 ¼

2 2 2 2 2 2

4 3⁄8 4 3⁄8 4 3⁄8 4 3⁄8 4 3⁄8 4 3⁄8

8 3⁄8 10 5⁄8 8 3⁄8 10 5⁄8 8 3⁄8 10 5⁄8 8 3⁄8 10 5⁄8 8 3⁄8 10 5⁄8 8 3⁄8 10 5⁄8

5 ¼ 5 ¼ 5 ¼ 5 ¼ 5 ¼ 5 ¼ 6 1⁄8 6 1⁄8 6 1⁄8

6 6 6 6 6 6

12 3 12 3 12 3 12 3 12 3 12 3

76 76 76 76 76 76

½ ½ ½ ½ ½ ½

2

1 ¼ 1 ½ 1 ½ 1 ½ 2 ½ 2 ½

2 ½

4011-11 or 4011-12

3 3 4 4

5 9⁄16 5 9⁄16 6 15⁄16 6 15⁄16

4425-6-B

4425-7-A 4425-7-B 4425-8-A

7 10 7 10 7 10

2 5⁄8 5 7⁄8 2 5⁄8 5 7⁄8 2 5⁄8 5 7⁄8

11 11 11

14 1⁄16 14 1⁄16 14 1⁄16

6 ¾ 6 ¾ 6 ¾

13 ½ 4 ½ 130 13 ½ 4 ½ 130 13 ½ — 139

9⁄16 9⁄16 9⁄16

6  2 ½

10 11⁄16 

* Opening in furnace shell or outer wall must be ½ " larger than dimension "D" to allow for mounting plate fillet and draft. • Warning: Mounting plate and tile can be separated from burner body for convenience during furnace construction; but for -2 through -6 sizes, tile must be set in wall with notches for pilot and flame rod in proper position relative to desired air pipe direction. † Pilot, Flame Detector, and Observation Port positions are interchangeable as long as Pilot and Flame Detector are in adjacent holes. ‡ ¼ " air pressure tap on -2, -3, -4, -5 and -6. 1⁄8 " air pressure tap on -7-A, -7-B and -8-A.  "Flower pot" type flange for -8-A. Note larger F dimension. § For 4425- -MB Burners, a second observation port is substituted for the Pipe Plug.  The milk bottle tile is not offered with the 4425-8-A Burner.

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSITON, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .

Bulletin 4425 Page 3