Combustion Catalog | Fives North American

Propane Operation | Tempest®

PROPANE OPERATION Main Air Pressure, (UA pressure tap), "w.c

4441-4-A

0.3

1.7

6.9

15.6

20.8

27.7

34.6

41.6

Air Flow, not burning (scfh)

6200

Air Flow, (scfh)

950

1350

2850

4000

— — — — — — — — —

5350

— — — — — — — — —

6800

Air Orifice  , UA-DA, (“w.c.) Gas Orifice  , UG-DG, (“w.c.)

0.5

1.0

3.9

9.2

16.5

24.6

0.3 0.3

0.4

1.0

1.8

3.2

4.8

Tile Pressure, DG ("w.c.)

0.5

2.2

4.8

8.3

12.5

Max. % XSAir, fs, ignition

1100

1300

1500

1750

1750

900

Max. % XSFuel, fs

30 30

30 30

30 30

30 30

30 30

30 30

Max. % XSFuel, ignition

Flame Length (in.)

16

18

22

24

24

24

Flame Diameter (in.)

2

3

3

4

4

4

4441-4-B

0.3

1.7

6.9

15.6

20.8

27.7

34.6

41.6

Air Flow, not burning (scfh)

8600

Air Flow, (scfh)

1350

1900

3800

5700

— — — — — — — — —

7600

— — — — — — — — —

9200

Air Orifice  , UA-DA, (“w.c.) Gas Orifice  , UG-DG, (“w.c.)

0.5

1.0

3.9

8.9

15.9

24.6

0.3

0.3

1.3

2.0

4.5

8.8

Tile Pressure, DG ("w.c.)

0.2

0.4

1.9

4.3

7.6

10.5

Max. % XSAir, fs, ignition

3000

3000

3200

3300

2800

1700

Max. % XSFuel, fs

30 30

30 30

30 30

30 30

30 30

30 30

Max. % XSFuel, ignition

Flame Length (in.)

16

18

18

20

24

26

Flame Diameter (in.)

3

3

4

4

6

6

Bulletin 4441 page 10

Made with FlippingBook flipbook maker