4441-8 Burners with 310 SST Metal "M" Tile | Tempest®

10.8 (280)

A-ID

9 (229)

.19" (4.8)

8.75 (222)

" F " Flange .63 (16) thick

" FL " Flange .63 (16) thick

MEDIUM VELOCITY TILE

HIGH VELOCITY TILE

Burner Designation

Burner Designation

A Ø

A Ø

"F" Mounting

"F" Mounting

4441-8-AMRH/FL 4441-8-BMRH/FL 4441-8-CMRH/FL "FL" Mounting

4441-8-AMRM/FL 4441-8-BMRM/FL 4441-8-CMRM/FL "FL" Mounting

4441-8-AMRH/F 4441-8-BMRH/F 4441-8-CMRH/F

3.75 (95) 4.25 (108) 4.88 (124)

4441-8-AMRM/F 4441-8-BMRM/F 4441-8-CMRM/F

4.88 (124) 5.50 (140) 6.13 (156)

Medium velocity tiles are also available with an exit 2 sizes larger than the high velocity tile. Because the medium velocity tiles have less exit restriction than the high velocity versions, the:

4441-8 with "M" Tile — 310 SST metal tiles for applications up to 1800°F (982°C) are available with flanged “F” or “FL” style mounting for the 4441-8-A, -B and -C burner sizes with the same high velocity tile exit sizes and tile length as the refractory and the Alumina/Mullite tiles. Unlike the smaller 4441's, the tile mounting flange is the same thickness as the “A” style Alumina/Mullite tiles so the “M” metal tiles can be used in the same mounting plate as the “A” style tiles. So a 310 SST “M” tile (on a 4441-8) can be substituted for a ceramic “A” style tile without having to replace the burner body or mounting plate.

— Tile exit velocity will be about 35% lower — Burner capacity will be 10-20% higher

— The flame length will be 30% longer — Gas pressure will be 20-40% lower — Excess air, lighting, and flame supervision limits should be the same as the high velocity burner at the same capacity.

See Sheet 4441-1 for additional details on the 4441-M with metal tile.