4442 Burner | 4441 Burner Cross-Reference
Bulletin 4441 page 23
The 4441 improves on the 4442 by adding these features:
The 4441 burner is an improved version of the 4442 and retains these features:
— Available with additional tile options
· Thin wall self-supporting ceramic, ideal for fiber wall · Thin wall tile with slotted exit · 310 SST metal tile
— Available with the same high velocity square block refractory tile or the Aardvark metal tile with threaded exit — Has the same mounting options, two ears or fully flanged — Air and gas connections that match the 4442 — High excess air operation
— Direct spark ignition over a much wider ratio range — Much better flame supervision when using flame rods
4442 Burner part number
4441 Burner part number
4442 Burner part number
4441 Burner part number
Cold Air Burners with "2 Eared" Mounting
Hot Air Burners with "Flanged" Mounting
4442-0 4442-1 4442-2 4442-3 4442-4
Not Available 4441-1-RRH/E 4441-2-RRH/E 4441-3-RRH/E 4441-4-ARRH/E 4441-4-BRRH/E 4441-5-RRG/E 4441-6-RRH/E 4441-7-RRH/E
4442-0-H 4442-1-H 4442-2-H 4442-3-H 4442-4-H 4442-4-S#1 4442-5-H 4442-6-H
Not Available Not Available Not Available
4441-3-RRH/F/H 4441-4-ARRH/F/H 4441-4-BRRH/F/H
4442-4-S
4442-5 4442-6 4442-7
4441-5-RRH/F/X2873 4441-6-RRH/F/X2874 4441-7-RRH/F/X2875
4442-7-H
Cold Air Burners with "Flanged" Mounting
"Aadvark" Burner with Metal Tile
4442-0-F 4442-1-F 4442-2-F 4442-3-F 4442-4-F 4442-4-FS 4442-5-F 4442-6-F
Not Available 4441-1-RRH/F 4441-2-RRH/F 4441-3-RRH/F 4441-4-ARRH/F 4441-4-BRRH/F 4441-5-RRH/F 4441-6-RRH/F 4441-7-RRH/F
4442A-2 4442A-3 4442A-4
4441A-2-RRH/T 4441A-3-RRH/T 4441A-4-ARRH/T 4441A-4-BRRH/T 4441A-5-RRH/T 4441A-6-RRH/T 4441A-7-RRH/T
4442A-4-S
4442A-5 4442A-6 4442A-7
4442-7F
WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.