Combustion Catalog | Fives North American

Natural Gas Operation | Tempest®

All Data:............................... is based on firing with ambient combustion air.

UA-DA:................................ Published data is reasonably accurate between 17 and 86 mbar (6.9 and 34.6"w.c.) main air pressure (UA) if piped with >5 diameters of straight pipe into burner. Square rooting the UA-DA pressure drops using the published 69 mbar (27.7"w.c.) data is reasonably accurate between 17-86 mbar (6.9-34.6"w.c.) air pressure. Below 17 mbar (6.9"w.c.) the UA-DA data is suspect and should not be used for accurate air metering. Square rooting will over-estimate air flow below 17 mbar (6.9"w.c.) and underestimate above 86 mbar (34.6"w.c.) . UG-DG:................................ UG-DG information can be used to approximate fuel gas flow. External gas orifices or O 2 analysis should be used for precise determination of fuel metering and air/fuel ratio.

Max % XSAir, fs Max % XSAir, UV Max % XSAir, flame rod Max % XSFuel, fs

fs - indicates the maximum flame supervisory XSAir or XSFuel using either a UV detector or the specified flame rod listed on the 4441 parts list.

Max % XSAir, ignition Max % XSFuel, ignition

ignition - indicates the maximum XSAir or XSFuel at which the integral igniter will light the burner.

DG:...................................... Tile pressures are average values and are subject to considerable variation (±10%)

NATURAL GAS OPERATION Main Air Pressure, (UA pressure tap), mbar

4441-1

2

4

17

39

52

69

86

103

Capacity, Nm3/h main air (not burning)

43

Capacity, Nm3/h burner (burning stoich)

5

7

16

24

27

33

37

41

Air Orifice  , (UA-DA) mbar Gas Orifice  , (UG-DG) mbar

1.0

1.7

7.2

17.7

24.1

32.8

39.3

48.5

0.2

0.5

2.5

5.5

6.2

9.7

12.4

14.9

Tile Pressure, (DG) mbar

1.4

2.2

9.2

20.2

26.9

35.1

44.0

52.3

Max. % XSAir, fs, ignition

400

600

900

2000

2000

2000

2000

2000

Max. % XSFuel, fs

30 30 152

30 30

30 30

30 30

30 30

30 30

30 30

30 30

Max. % XSFuel, ignition

Flame Length, mm

178

178

203

229

254

254

254

Flame Diameter, mm

19

19

19

25

25

25

25

25

4441-2

.7

4

17

39

52

69

86

103

Capacity, Nm3/h main air (not burning)

72

Capacity, Nm3/h burner (burning stoich)

5

12

28

44

51

59

67

72

Air Orifice  , (UA-DA) mbar Gas Orifice  , (UG-DG) mbar

0.4

3.1

9.2

22.4

28.4

41.3

52.0

63.0

0.1

0.7

3.2

7.5

10.9

16.7

21.1

21.4

Tile Pressure, (DG) mbar

0.5

2.0

7.2

14.7

19.2

24.4

29.9

35.6

Max. % XSAir, fs, ignition

400

600

900

2000

2000

2000

2000

2000

Max. % XSFuel, fs

30 30 152

30 30

30 30

30 30

30 30

30 30

30 30

30 30

Max. % XSFuel, ignition

Flame Length, mm

203

254

254

254

254

279

254

Flame Diameter, mm

25

51

38

38

51

51

51

51

Bulletin 4441M page 4

Made with FlippingBook flipbook maker