Combustion Catalog | Fives North American

Ordering Information | Tempest®

H

4441 -

-

Air/Gas connections Blank = NPT M = BSPT

Fuel Blank = Natural Gas fuel only P = Propane fuel only (-1 thru -4-B only)

Tile Exit Size H = High Velocity Tile (standard) M = Medium Velocity Tile (M tiles) See Sheet 4441-1 for details Mountings E = Eared (with -1 thru -7 "R" tile only) F = Flanged (optional with "R" tile and standard with all others) FL = Flanged longer tile mounting with 292 mm (11") tile length (for -1 thru -8 with "A" material tile only)

4441 Capacities @ 6.9kPa (27.7"w.c.)

Input @ 10% xsa Btu/h HHV (kW LHV) 114,000 (30) 200,000 (53) 300,000 (79) 477,000 (126) 627,000 (166) 864,000 (228) 1,364,000 (360) 2,000,000 (529) 2,909,000 (770) 3,818,000 (1010) 4,910,000 (1299)

Air Flow scfh (Nm 3 /h) 1250 (33) 2200 (59) 3300 (88) 5250 (140) 6900 (184) 9500 (254) 15,000 (401) 22,000 (588) 32,000 (856) 42,000 (1124) 54,000 (1444)

size -1 = 1 ¼ " -2 = 1 ¼ " -3 = 1 ½ " Air Pipe

-4-A = 2" -4-B = 2"

-5 = 2 ½ " -6 = 3" -7 = 4"

Tile Exit Shape R = Round S = Slotted ("A" tile only)

-8-A = 6" -8-B = 6" -8-C = 6"

Tile Material R = Square block refractory -1 to -7 = Square, -8-A, -B, -C = Round A = Alumina/Mullite M = Metal, 310 Stainless Steel Alloy, See Sheet 4441-1 for details J = Square block refractory with 309 SST tile jacket (-1 thur -7 only) See Bulletin 4441A for "Aardvark" alloy tile

All 4441 burners come with a direct spark igniter, an optional pilot tip is available for 4441-8 sizes.

Examples: 4441-4-AASH/F = -4-A Capacity 4441 Burner with an Alumina/Mullite slotted high velocity tile, with flanged mounting. 4441-2-RRH/E = -2 Capacity 4441 Burner with a square refractory high velocity tile, with eared mounting. M4441-7-ARH/F = -7 Capacity 4441 Burner with an Alumina/Mullite round high velocity tile, with flanged mounting, BPST air/gas connections.

SPECIAL 4441 INFORMATION

Besides the standard options listed above, 4441 Tempest® burner are available in many other special configurations.

Hot Air: Most 4441 configurations can be built with special components for use with preheated air to 800°F (427°C)

Medium velocity tiles: Many 4441 configurations can be assembled with tiles larger exists to deliver lower flame velocities. —These sizes can be special ordered with a one size larger tile exit: -1,-2,-3,-4-A, -5, -6, -8-A, -8-B —These sizes can be special ordered with two sizes larger tile exit: -1, -2, -3, -5, -8-A

Extra high velocity Tempest® tiles: Many 4441 configurations can be assembled with tiles with smaller exists to deliver even higher flame velocities. These sizes can be special ordered with a one size smaller tile exit: -2, -3, -4-A, -4-B, -6, -7, -8-B, -8-C

Special tile mounting plates: 4441 burners can be engineered with special mounting plates, for example: —Built in connections for LNI low NOx injectors —Custom tile mounting plates to match existing burner mounting configurations

All 4441 burners come with a direct spark igniter, an optional pilot tip is available for 4441-8 sizes.

Bulletin 4441M page 15