Combustion Catalog | Fives North American

Recommended Piping | Tempest®

RECOMMENDED PIPING FOR 4441 AND 4442 TEMPEST GAS BURNERS

IMPERIAL AND METRIC EQUIVALENTS

Gas/Air Ratio Regulator (shown w/ bypass, required within 4' of burner)

Limiting Orifice Valve required within 1' of burner H

Table 1. Recommended component selection for 4441/4442 Tempest burners with StepFire TM Control.

Air Side

Fuel Side

Burner Size

A

B

C

D

E

F

G

H

I

-1 -2 -3

1¼" 1¼" 1½"

1¼" 1¼" 1½"

1¼" 1¼" 1½"

1¼" 1¼" 1½"

¾" ¾" ¾"

¾" ¾" ¾"

¾" ¾" ¾"

¾" ¾" ¾"

¾" ¾" ¾"

-4-A -4-B

2" 2" 3" 4"

2" 2" 3" 4"

2" 2" 3" 4"

2" 2" 3" 4"

1" 1"

1" 1"

1" 1"

1" 1"

1" 1"

-5 -6 -7

2½"

2½"

2½"

2½"

1¼" 1½"

1¼" 1½"

1¼" 1½"

1¼" 1½"

1¼" 1½"

2"

2"

2"

2"

2"

Legend for Table 1

FUEL E – 8697 Metering Orifice F – 7216- - BP Regulator (with bypass) G – Threaded Pipe Union H – 1807 Limiting Orifice Valve J – 8773 Flexible Pipe

AIR A – 8697/8695 Metering Orifice (optional) B – 1122 Manual Air Valve C – Air Cycle Valve D – 8770/8773 Flexible Connection or 2947 Blower Sleeve

pipe code

-04

-03

-02

-01 ½ "

-0 ¾ "

-1 1"

-2

-3

-4 2"

-5

-6 3"

-7 4"

NPS

1⁄8 "

¼ "

3⁄8 "

1 ¼ "

1 ½ "

2 ½ "

DN

6mm 8mm 10mm 15mm 20mm 25mm 32mm 40mm 50mm 65mm 80mm 100mm

NPS stands for nominal pipe size DN stands for diameter nominal

Bulletin 4441M page 16