Combustion Catalog | Fives North American

All Data:............................... is based on firing with ambient combustion air.

UA-DA:................................ Published data is reasonably accurate between 6.9 and 34.6"w.c. (1.7 and 8.6 kPa) main air pressure (UA) if piped with >5 diameters of straight pipe into burner. Square rooting the UA-DA pressure drops using the published 27.7"w.c. (6.9 kPa) data is reasonably accurate between 6.9-34.6"w.c. (1.7-8.6 kPa) air pressure. Below 6.9"w.c. (1.7 kPa) the UA-DA data is suspect and should not be used for accurate air metering. Square rooting will over-estimate air flow below 6.9"w.c. (1.7 kPa) and underestimate above 34.6"w.c. (8.6 kPa). UG-DG:................................ UG-DG information can be used to approximate fuel gas flow. External gas orifices or O 2 analysis should be used for precise determination of fuel metering and air/fuel ratio.

Max % XSAir, fs Max % XSAir, UV Max % XSAir, flame rod Max % XSFuel, fs

fs - indicates the maximum flame supervisory XSAir or XSFuel using either a UV detector or the specified flame rod listed on the 4441 parts list.

Max % XSAir, ignition Max % XSFuel, ignition

ignition - indicates the maximum XSAir or XSFuel at which the integral igniter will light the burner.

DG:...................................... Tile pressures are average values and are subject to considerable variation (±10%)

NOTE: The capacity of the burners has not changed but static pressure has been transitioned to measuring static pressure in imperial units by inches of water column. Previous versions of the bulletin measured static air pressure in ounces per square inch. Conversion: 1 osi = 1.73"w.c.

NATURAL GAS OPERATION

4441-1 HV Air Pressure UA osi ("w.c.) Air Flow, not burning (scfh)

0.5 (0.9")

1 (1.7")

4 (6.9")

9 (15.6") 16 (27.7")

20 (34.6")

1650 1200

Air Flow (scfh)

200

300

580

880

1350

Air Orifice  , UA-DA, (in.w.c.) Gas Orifice  , UG-DG, (in.w.c.)

0.4

0.6 0.3

2.3 0.8 4.4

5.3

9.8 3.2 17.3

12.2

0.1

1.7 10

4

Tile Pressure DG (in.w.c.) Max. % XSAir, fs, ignition

0.55 400

1

21.6

600

900

2000

1500

2000

Max. % XSFuel, fs

30 30

30 30

30 30

30 30

30 30

30 30

Max. % XSFuel, ignition Flame Length (in.) Flame Diameter (in.)

6

8

7

8

8

9

0.75

1

1

1

1

1

4441-1 MV Air Pressure UA osi ("w.c.) Air Flow, not burning (scfh)

0.2 (0.3")

1 (1.7")

4 (6.9")

9 (15.6") 16 (27.7")

1800 1700

Air Flow (scfh)

220 0.25

400

850

1250

Air Orifice  , UA-DA, (in.w.c.) Gas Orifice  , UG-DG, (in.w.c.)

1.3

5.3

12.1 3.8 2.8

21.6

0.1

0.4 0.3

1.7 1.2

6.7 4.9

Tile Pressure DG (in.w.c.) Max. % XSAir, fs, ignition

0.07 300

600

900

2000

1900

Max. % XSFuel, fs

30 30

30 30 10 1.5

30 30

30 30

30 30

Max. % XSFuel, ignition Flame Length (in.) Flame Diameter (in.)

10

11

12

12

2

1.5

1.5

1.5

Sheet 4441-1 page 4