Combustion Catalog | Fives North American

NATURAL GAS OPERATION

4441-2 HV Air Pressure UA pressure tap ("w.c.)

0.2 (0.3")

1 (1.7")

4 (6.9")

9 (15.6")

16 (27.7")

20 (34.6")

Air Flow, not burning (scfh)

2790 2370

Air Flow (scfh)

255 0.15

550 0.9 0.3 0.7

1100

1680

2700 20.6

Air Orifice  , UA-DA, (in.w.c.) Gas Orifice  , UG-DG, (in.w.c.)

3.7 1.14

8.8 2.7

16.4

0.1 0.1

5.3

7

Tile Pressure DG (in.w.c.) Max. % XSAir, fs, ignition

3

6.1

10.2

12.4

200

1500

2000

3000

3000

3000

Max. % XSFuel, fs

30 30 10 1.5

30 30

30 30

30 30 10 1.5

30 30 10 1.5

30 30

Max. % XSFuel, ignition Flame Length (in.) Flame Diameter (in.)

9

11

11

1.5

1.5

1.5

4441-2 MV Air Pressure UA pressure tap ("w.c.)

0.2 (0.3")

1 (1.7")

4 (6.9")

9 (15.6")

16 (27.7")

Air Flow, not burning (scfh)

2850 2650

Air Flow (scfh)

300

650

1320

2000

Air Orifice  , UA-DA, (in.w.c.) Gas Orifice  , UG-DG, (in.w.c.)

0.3 0.1

1.3

5.4

12.5

22.7

0.5 0.3

1.7 1.1

4

6.6 3.6

Tile Pressure DG (in.w.c.) Max. % XSAir, fs, ignition

0

2.1

600

1500

2000

3000

3000

Max. % XSFuel, fs

30

30 30

30 30

30 30

30 30

Max. % XSFuel, ignition Flame Length (in.) Flame Diameter (in.)

30

13

11

13

13

12

3

2

2

2

3

4441-3 HV Air Pressure UA pressure tap ("w.c.)

0.2 (0.3")

1 (1.7")

4 (6.9")

9 (15.6")

16 (27.7")

20 (34.6")

Air Flow, not burning (scfh)

3850 3250

Air Flow (scfh)

400 0.25

800

1600

2350

3800

Air Orifice  , UA-DA, (in.w.c.) Gas Orifice  , UG-DG, (in.w.c.)

0.9 0.4 0.7

3.5 1.3 2.9

7.8

14.2 6.6 12.8

18.2

0.1 0.2

3

7.9

Tile Pressure DG (in.w.c.) Max. % XSAir, fs, ignition

6.6

14

1500

2000

3000

4000

4000

3000

Max. % XSFuel, fs

30 30

30 30

30 30

30 30

30 30

30 30 8.5 2.5

Max. % XSFuel, ignition Flame Length (in.) Flame Diameter (in.)

8 3

9 3

8 2

7 3

7 3

4441-3 MV Air Pressure UA pressure tap ("w.c.)

0.2 (0.3")

1 (1.7")

4 (6.9")

9 (15.6")

16 (27.7")

Air Flow, not burning (scfh)

4200 3950

Air Flow (scfh)

570 0.25

1000

1920

2930

Air Orifice  , UA-DA, (in.w.c.) Gas Orifice  , UG-DG, (in.w.c.)

1.4

5.8 2.2 0.7

13.1

23.5

0.2

0.6 0.2

5.1 1.6

10.1 2.8

Tile Pressure DG (in.w.c.) Max. % XSAir, fs, ignition

0

1500

3000

3000

4000

4000

Max. % XSFuel, fs

30 30

30 30

30 30

30 30

30 30

Max. % XSFuel, ignition Flame Length (in.) Flame Diameter (in.)

12

12

10

11 4

7

4

3

4

4.5

Sheet 4441-1 page 5

Made with FlippingBook flipbook maker