Combustion Catalog | Fives North American

Dimensions & Parts List 4441DMC-1 Page 2

4441DMC SERIES SPARE PARTS

A

Furnace Mtg Gasket

Tile Mtg. Gasket

¾ " NPT Flame Supervisory Port (flame supervisory components must be ordered separately) ‡

Body Gasket

Observation Port

37-0006/CI

Tile

Igniter

Burner only*

DG

DA

37-0289/HR

UA

Fives North American

Cleveland, OH USA

Mounting and Insulation Assembly

Flanged Mounting standard with slotted tile

A

Slotted Tile

Burner designation

Part Name

4441DMC-3

4441DMC-4-A

4441DMC-4-B

4441DMC-5

4441DMC-6

4441DMC-7

Natural Gas

Burner Only*

4441DMC-3/BO

4441DMC-4-A/BO 4441DMC-4-B/BO 4441DMC-5/BO 4441DMC-6/BO 4441DMC-7/BO

All Models

Body Gasket

4-25428-1

4-25427-1

4-25427-1

4-6102-1

4-6102-1

4-6102-1

R240-2100 8790-0

Igniter Observation Port Flame Rod Assembly‡ Furnace Mtg. Gasket

4-25432-1

4-25432-3

4-25432-3

4-25432-4

4-25432-4

4-25432-2

4-51882-1

4-51882-2

Slotted Tile

Slotted Tile†

4-27596-3

4-27596-4 4-25716-1 4-25484-1

4-27596-4 4-25716-1 4-25484-1

4-25470-4 4-25716-2 4-25485-1

4-25470-5 4-25716-2 4-25485-1

4-25470-6 4-25716-2 4-25485-1

Mounting & Insulation ass'y 4-25716-1

Tile Mtg. Gasket

4-25484-1

* Burner Only includes Body Gasket, Stabilizer, Observation Port, Nameplate, and plugs. † Slotted tile orientation can be changed by loosening the bolts fastening the body to the mounting and adjusting the tile accordingly. ‡ Order separately.

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com