Combustion Catalog | Fives North American

Performance Data | Tempest® 4442 Burner

Air Pressure, osi (UA Pressure Tap)

4442-2

0.5 380

1

4

9

14

16

20

24

Capacity, scfh main air (burning stoichiometric)

530

1090

1640

2100

2300

2600 2800

Air Orifice  , (UA-DA) in. w.c . Gas Orifice  , (UG-DG) in. w.c. Tile Pressure, (DG) in. w.c. Max. % XSAir, stability, UV Max. % XSFuel, stability, UV

† † †

† † †

† † †

† † †

8.9 3.1 9.7

10

13

15.5

3.5 11.5

5

6

15

17

1000

1000

1500

2000

2000

2000

2000 1500

20+

30+

30+

30+

30+

30+

30+

30+

Flame Length, in. Flame Diameter, in.

6 2

8 2

9 2

10

10

10

12

14

2

2

2

2

2

Capacity, scfh main air (not burning)

2800

Max. % XSA, flame rod Max. % XSF, flame rod

— —

100 30+

80

25

— — 35

75

— — 35

— — 45

30+

30+

30+

Minimum gas flow lighting, scfh Maximum gas flow lighting, scfh

5

10

25

30

35

40

180

250

250

230

215

220

230

Air Pressure, osi (UA Pressure Tap)

4442-3

0.5 560

1

4

9

14

16

20

24

Capacity, scfh main air (burning stoichiometric)

800

1620

2400

3050 3250

3700

4000

Air Orifice  , (UA-DA) in. w.c. Gas Orifice  , (UG-DG) in. w.c. Tile Pressure, (DG) in. w.c. Max. % XSAir, stability, UV Max. % XSFuel, stability, UV

† † †

† † †

† † †

† † †

15.1 3.9 7.9

16.5 4.4 9.0

21

25.5

5.9

6.7

10.5

12.8

1000

1500

3000+

3000+ 3000+ 3000+ 3000+ 3000+

30+

30+

30+

30+

30+

30+

30+

30+

Flame Length, in. Flame Diameter, in.

12

15

16

16

18

20 2.5

21

22

2

2.5

2.5

2.5

2.5

3.0

3.0

Capacity, scfh main air (not burning)

3760 1400

Max. % XSA, flame rod Max. % XSF, flame rod

— — 10 25

400 30+

900 30+

1000

— — 20

— — 30

— — 35

30+

30+

Minimum gas flow lighting, scfh Maximum gas flow lighting, scfh

10 35

15

20

25

65

100

100

155

160

180

Air Pressure, osi (UA Pressure Tap)

4442-4

0.5

1

4

9

14

16

20

24

Capacity, scfh main air (burning stoichiometric)

900

1250

2500

4000

5200

5400

6100

7000

Air Orifice  , (UA-DA) in. w.c. Gas Orifice  , (UG-DG) in. w.c. Tile Pressure, (DG) in. w.c. Max. % XSAir, stability, UV Max. % XSFuel, stability, UV

† † †

† † †

† † †

† † †

11.7 4.5 7.5

13.6

17.0 6.4

20.5

5

8.2

8.4

10

12

1500

2500

3000+

3000+ 3000+ 3000+ 3000+ 3000+

30+

30+

30+

30+

30+

30+

30+

30+

Flame Length, in. Flame Diameter, in.

15

15

16

20

20

20

21

24

3

3

4

5

5

5

5

5

Capacity, scfh main air (not burning)

6200 1500

Max. % XSA, flame rod Max. % XSF, flame rod

— — 15 75

1000

1400

2000

— — — —

— —

— — 80

30+

30+

30+

30+

Minimum gas flow lighting, scfh Maximum gas flow lighting, scfh

15

35

50

75

80

100

210

330

230

240

260

Air Pressure, osi (UA Pressure Tap)

4442-4-S (Flame rod not recommended) Capacity, scfh main air (burning stoichiometric)

0.5

1

4

9

14 — — — — — — — —

16

20 — — — — — — — —

24

1350

1850

3900

6300

8900

11 000

Air Orifice  , (UA-DA) in. w.c. Gas Orifice  , (UG-DG) in. w.c. Tile Pressure, (DG) in. w.c. Max. % XSAir, stability, UV Max. % XSFuel, stability, UV

— 9.1 —

6.0

1000

1000

600

600

250

250

30

30

30

30 22

30 25

30 30

Flame Length, in. Flame Diameter, in.

17

18

19

3

3

3

3

3

4

Capacity, scfh main air (not burning) Minimum gas flow lighting, scfh Maximum gas flow lighting, scfh

11 000

40 75

50

75

100 300

— —

175

— —

250 400

100

250

400

Bulletin 4442 Page 5

Made with FlippingBook flipbook maker