Hot Air Capacity | Tempest® 4442 Burner
Air Pressure, osi (UA Pressure Tap)
4442-4-H–800°F Main Air
1
4
9
16
22
Capacity, scfh main air (burning stoichiometric)
955
1900
2850 3880 4530
Max. % XSAir Max. % XSFuel
1500 3000
3000
3000+ 3000+
30+
30+
30+
30+
30+
Flame Length, in. Flame Diameter, in.
8
12
14
16
16
2.5
2.5
2.5
2.5
2.5
Air Pressure, osi (UA Pressure Tap)
4442-5-H–800°F Main Air
1
4
9
16
22
Capacity, scfh main air (burning stoichiometric)
1730
3420
5050 6800 8050
Max. % XSAir Max. % XSFuel
2000+ 2000+ 2500+ 3000+ 3000+
30+
30+
30+
30+
30+
Flame Length, in. Flame Diameter, in.
20
22
22
24
25
3
2.5
2.5
2.5
2.5
Air Pressure, osi (UA Pressure Tap)
4442-6-H–800°F Main Air
1
4
9
16
20
Capacity, scfh main air (burning stoichiometric)
2300 4800
7600 9800 11000
Max. % XSAir Max. % XSFuel
2000 3000+ 3000+ 3000+ 3000+
30+
30+
30+
30+
30+
Flame Length, in. Flame Diameter, in.
24
24
30
36
36
6
6
6
6
6
Air Pressure, osi (UA Pressure Tap)
4442-7-H–800°F Main Air
1
4
9
16
20
Capacity, scfh main air (burning stoichiometric)
3600 7000 10800 13000 15000 2000+ 2000+ 3000+ 3000+ 3000+
Max. % XSAir Max. % XSFuel
30+
30+
30+
30+
30+
Flame Length, in. Flame Diameter, in.
24
24
30
30
36
6
6
7
7
7
Bulletin 4442 Page 8