Combustion Catalog | Fives North American

Product Overview | 4445 & 4445N Tempest®

— Standard lengths available for 9" to 40" wall thicknesses longer lengths available on request — Field adjustable mounting flange — Suitable for up to 2900°F operation — Low NOx emissions — Tile options to fit the application: – Two tile materials: alumina/mullite, and metal alloy – Two tile exit shapes: round and slotted Round tiles produce high forward thrust, Slotted tiles produce wider and thinner flames with more entrainment. FEATURES

High velocity gas burner for thick wall kilns and furnaces — standard lengths available for 9" to 40" wall thicknesses

Enhanced temperature uniformity and heat transfer promoted by recirculation of combustion products, improve both product quality and productivity in many kilns and furnaces. True high velocity burners entrain and recirculate products of combustion (poc) volumes seven or more times greater than the actual tile exit gas volume, potentially eliminating the need for excess air operation or hot gas recirculation fans. Designed for mounting in thick walls, the 4445 Tempest High Velocity Gas Burner places the tile discharge at the hot face, increasing entrainment and providing superior uniformity. Although used predominantly in ceramic kilns, other applications that can benefit from the 4445’s high velocity characteristics and design features include:

UPDATED 4445N FEATURES

The new 4445N-2 through -4-B design replaces the same size 4445 burners, and has many improvements, including:

— 90° Air inlet for all sizes — Built-in gas limiting orifice valve (sizes -2 through -4-B) — New baffle to prevent incorrect placement of igniter — Simplified tile mounting for easier tile replacement — Improved ceramic insulators for igniter and flame rod To maintain a common naming system the 4445-5 and -6 sizes (which have always had a 90° air inlet) have been renamed 4445N-5 and 4445N-6. Most spare parts for the 45° air inlet legacy burners will continue to be available, and many of the 4445N improvements will be incorporated into the legacy 4445 replacement parts.

Box and Car Heat Treat Furnaces Galvanizing Tanks Lead and Zinc Pots Salt Baths and other thick wall applications

4445/4445N Performance Data

Burner Size

-2

-3

-4-A

-4-B

-5

-6

Air Flow, not burning at 16 osig (scfh) Air Flow, Stoic at 16 osig (scfh)*

2200 1950 1500

3600 3250 1000

6500 5700 1000

7500 6900 1000

10900

17900 15000

9260

Max. % XSA (ignition and flame rod limit)** Max. % XSF (ignition and flame rod/UV limit)

1500

1000

30

30

30 24

30 28 4.5

30 24

30 26

Flame Length (in.), Stoic at 16 osig air Flame Diameter (in.), Stoic at 16 osig air Gas Pressure (osig), Stoic at 16 osig air

12

16

2

3 9

4

3

4

10

10

9

8.0

8.4

*Nominal capacities. Actual capacities may vary based on burner length and tile selection. ** UV limits may differ.