Combustion Catalog | Fives North American

Engineering Data | 4445N Tempest®

Natural Gas, USCS Main Air Pressure, (UA pressure tap)

osi "w.c. mbar

4445N-5

0.2 0.3 0.9

1

4

9

16

20

1.7

6.9 17.2

15.6

27.7

34.6

4.3

39

69

86

Air Flow, not burning scfh (Nm 3 /h)

10 900 (291)

Air Flow, scfh

1000 (26.7)

2150 (57.5)

4350 (116.3)

3700 (179)

9200 (246)

10300

Air Flow, (Nm 3 /h)

(275)

Air Orifice UA-DA, "w.c. (mbar) Gas Pressure Stoic. air "w.c. (mbar)

0.1 (0.2) 0.2 (0.5) 0.16 (0.4)

1.0 (2.5) 0.9 (2.2) 0.7 (1.8)

2.6 (6.5) 3.6 (9.0) 3.2 (7.9)

5.5 (13.7) 8.3 (20.7) 7.3 (18.3)

10.3 (25.6) 13.8 (34.3) 12.3 (30.6)

13.0 (32.3)

17.0 (50) 15.2 (38)

Gas Pressure @ 10% excess air "w.c. (mbar)

Max % Excess Air, ignition

600 100 200

1000 1400

1400 1600 1000

1400 1600 1000

1000 1500 1000 1000

800 1000 1000 600

Max % Excess Air, Flame Rod flame signal Max % Excess Air, UV flame signal S, M length Max % Excess Air, UV flame signal L, XL Length

500 200

— 30

500

700

Max % XS Fuel, ignition/flame signal

30

30

30

30

30

Flame Length inches (mm) Flame Diameter inches (mm)

22 (559) 4.0 (102)

22 (559) 4.0 (102)

24 (610) 4.0 (102)

24 (610) 4.0 (102)

24 (610) 4.0 (102)

24 (610) 4.0 (102)

4445N-6

0.2 0.3 0.9

1

4

9

16

20

osi "w.c. mbar

1.7

6.9 17.2

15.6

27.7

34.6

4.3

39

69

86

Air Flow, not burning scfh (Nm 3 /h)

17900 (478)

Air Flow, scfh

1800 (48.1)

3400

6800

10600

14400

15700 (420)

Air Flow, (Nm 3 /h)

(91)

(182)

(283)

(385)

Air Orifice UA-DA, "w.c. (mbar) Gas Pressure Stoic. air "w.c. (mbar)

0.05 (0.1) 0.4 (1.0) 0.3 (0.8)

0.3 (0.75) 1.0 (2.5)

2.1 (5.2)

3.9 (9.7)

5.1 (12.7)

1.4 (3.5) 1.1 (2.8)

4.8 (11.9) 4.2 (10.4)

10.2 (25.4) 8.9 (22.1)

17.2 (42.8) 15.0 (37.4)

25.1 (62.5)

Gas Pressure @ 10% excess air "w.c. (mbar)

21.7 (54)

Max % Excess Air, ignition

1000 1200 1200 1000

1000 1400 1400 1200

800 1200 1200 900

800 1200 600 600

600 800 500 500

600 800 700 500

Max % Excess Air, Flame Rod flame signal Max % Excess Air, UV flame signal S, M length Max % Excess Air, UV flame signal L, XL Length

Max % XS Fuel, ignition/flame signal

30

30

30

30

30

30

Flame Length inches (mm) Flame Diameter inches (mm)

24 (610) 4.0 (102)

24 (610)

24 (610)

24 (610) 5.0 (127)

24 (610) 5.0 (127)

25 (635) 5.0 (127)

4.0 (102) 4.0 (102)

Bulletin 4445/4445N Page 5

Made with FlippingBook flipbook maker