Combustion Catalog | Fives North American

Dimensions | 4445-2 thru -4-B Legacy Tempest®

Field adjustable mounting flange - 4 slots, 5/8 (16) dia., eq. spaced on 7.0 (178) - BC

Z

1/8" NPT DA Pressure Tap

B-NPT Gas Connection

J 1 or J 2

Ø 8.5 (216)

Ø 8.0 (203)

Ø 3.5 (89)

Ø 4.0 (102)

H

A-NPT Air Inlet (angled at 45°)

1/8" NPT main air pressure tap UA

5/8" (16)

Q

L

4445-2 through -4-B

M

J 1 -dia.

J 2

N

K-dia.

Slotted Tile (for ceramic only)

Round Tile

"L" dim. = overall length

Burner

designation

A

B

J 1

J 2

K

M

N

-S

-M

-L

-E

4445-2

1 ¼ 1 ½

2.1 (53) 2.1 (53) 2.4 (61)

1.09 (28)

1.75 (44)

0.54 (14)

¾ ¾ ¾ ¾

4445-3

1.44 (37)

2.25 (57)

0.74 (19)

26.0 (660)

34.38 (873)

44.38 54.38

(1127)

(1381)

4445-4-A 4445-4-B

2 2

1.75 (44)

2.69 (68) 2.69 (68)

0.92 (23)

1.94 (49)

1.13 (29)

"H" dim.

"Z" dim. = insertion depth

"Q" dim. = tile to air flange

Burner

designation

-S

-M -L -E

-S

-M

-L

-E

-S

-M

-L

-E

4445-2 4445-3

9.0

11.75 (298)

17.6

26.0 (660)

36.0 (914)

48.0 (1219)

9-12

12-20

12-30

12-40

(229)

(448)

(229-305) (305-508) (305-762) (305-1016)

4445-4-A 4445-4-B

 These tiles are not contoured at the discharge end.  SPL = max. "Z" dimension required plus approximately 6" -- for estimating purposes only.

Bulletin 4445/4445N Page 8

Made with FlippingBook flipbook maker