Capacity | 4482 ATP™ Burner
RANGE OF FLAME LENGTHS and DIAMETERS (2000°F Furnace) in feet with 8 psig gas Air/gas ratio set for 10% excess air.
COMBUSTION AIR CAPACITIES, scfh long flame mode Capacities are reduced up to 10% in short flame mode.
FLAME DIA. (full capacity) long or short
SHORT FLAME (10% reduced capacity) air pressure
LONG FLAME (full capacity) air pressure
Burner
air pressure
10"w.c. † 40 700 71 500 89 200 113 000 160 000 200 000 264 000 337 000 419 000 509 000 608 000
designation
0.1"w.c.* 4 070 7 150 8 900 11 300 16 000 20 000 26 000 33 000 42 000 51 000 61 000
6"w.c. 31 500 55 300 69 100 87 700 124 000 155 000 205 000 261 000 324 000 361 000 471 000
Burner designation 6"w.c. 10"w.c. 6"w.c. 10"w.c. 4482-8 3 ½ 6 8 15
4482-8 4482-9
2.5 2.5
4482-9
5 6
8 8 9 9
10 12 15 16 18
15 16 18
4482-10-A 4482-10-B
4482-10-A 4482-10-B
3 3 3
7 7
4482-12 4482-14 4482-16 4482-18 4482-20 4482-22 4482-24
4482-12 4482-14 4482-16 4482-18 4482-20 4482-22 4482-24
20 24 30 34 40 45 50
9
12
3.5
11
14 18 22 25 28
24 28 32 36 45
3.5
14 18
4 4
20 23
4.5
5
†max. recommended press.
*min. air rate
TYPICAL SINGLE BURNER ATP FLOW CONTROL SCHEMATIC
Combustion Air
Air Control Valve
P Transmitter
8000 Series Electronic Ratio Controller
Flow Control
P Transmitter
Natural Gas from Fuel Train
Gas Control Valve
Jet Gas
L S
Manual Flame Length Adjustments L - long flame (forward gas) S - short flame (tangential gas)
4014 Gas Boosted Pilot (See Sheet 4014 and Dims. & Installation 4482 for pilot sizes.)
Pilot Air
Pilot Gas
Bulletin 4482 Page 2