Combustion Catalog | Fives North American

North American ATP™ Adaptive Thermal Profile Low NOx Burners for High Temperature Applications

Dimensions & Installation 4482

DIMENSIONS inches

Burner designation

B  †

C D E F G H °

K L M N °

A 

J

P

Q

S

T

U

4482-8 4482-9

6 8

2 ½ 2 ½ 2 ½ 2 ½ 2 ½ 2 ½ 2 ½

16 16 20 20 20 20 24 24 24 24 24

8 22 ½ 8 22 ½

9 ½

11

24 ½ 24 ½ 26 ½ 26 ½ 28 ½ 30 ½ 32 ½ 36 ½ 38 ½ 40 ½ 42 ½

26 ¼ 26 ¼ 28 ¼ 28 ¼ 30 ¼ 32 ¼ 34 ¼ 38 ¼ 40 ¼ 42 ¼ 44 ¼

5 1⁄8 5 1⁄8 5 1⁄8 5 1⁄8 5 1⁄8 5 1⁄8 5 1⁄8

¾ ¾ ¾ ¾ ¾ ¾ ¾

¾ ¾ ¾ ¾ ¾ 7⁄8 7⁄8 7⁄8 7⁄8 7⁄8 7⁄8

7⁄8 7⁄8

11 ¾ 14 ¼ 14 ¼ 18 ¾ 21 ¼ 22 ¾ 17

13 ½

4482-10-A 4482-10-B 4482-12 4482-14 4482-16 4482-18 4482-20 4482-22 4482-24

10 10 12

1 1 1

12 15 12 15 12 15 12 15 16 11 ¼ 16 11 ¼ 20 9 20 9 20 9

16 16 19 21

13 7⁄8 15 7⁄8 17 7⁄8 19 7⁄8 21 7⁄8 23 7⁄8

1 1⁄8 1 1⁄8

23 ½

— ¾ ¾ ¾ ¾

— 7 ½ 7 ½ 7 ½ 7 ½

4 4 4 4

1 1 1 1

8 22 ½ 8 22 ½ 8 22 ½ 8 22 ½

9 1 ¼ 9 1 ¼ 9 1 ¼ 9 1 3⁄8

25

7 11⁄16 7 11⁄16 7 11⁄16 7 11⁄16

25 26

27 ½ 29 ½

29 ½

32

†-8 thru -16, 2 ½ " threaded; -18 thru -24, 4" ANSI flange

Burner

Pilot assembly designation

W °

BB CC 

DD EE 

GG 

designation

V

X

Y

Z

AA

FF

4482-8 4482-9

13 ½ 13 ½ 14 ½ 14 ½ 15 ½ 16 ½ 17 ½ 19 ½ 21 ½ 22 ½ 23 ½

11 ¼ 11 ¼

16 16 18 18

12 ¾ 12 ¾ 14 3⁄8 14 3⁄8 15 7⁄8 16 7⁄8 17 ½ 19 5⁄8 20 ½ 22 3⁄8 23 ½

7 3⁄8 7 3⁄8 7 3⁄8 7 3⁄8 7 3⁄8 7 3⁄8 7 3⁄8 8 ¼ 8 ¼ 8 ¼ 8 ¼

38 1⁄8 38 1⁄8 41 ¾ 41 ¾ 45 ¾ 47 ¾ 48 7⁄8 52 3⁄8 54 ¼ 57 1⁄8 59 ¼

2 3⁄16 2 3⁄16 2 ¾ 2 ¾ 2 7⁄8 2 7⁄8 2 7⁄8 2 7⁄8 2 7⁄8 2 7⁄8 2 7⁄8

1 ¼ 1 ¼ 1 ½ 1 ½

14 14 16 16 18

20 20 22 22 24

63 5⁄8 63 5⁄8 70 7⁄8 70 7⁄8 79 1⁄8 82 7⁄8 92 ¾ 93 ½ 99 ¼ 85

11 11

4014-1-T 4014-1-T 4014-2-T 4014-2-T 4014-3-AT 4014-3-AT 4014-3-AT 4014-3-BT 4014-3-BT 4014-3-BT 4014-3-BT

4482-10-A 4482-10-B 4482-12 4482-14 4482-16 4482-18 4482-20 4482-22 4482-24

9 9

13 13 14 16 18 21 22 24 26

9 9

20 ½ 21 ½ 22 ½ 23 ½ 24 ½ 25 ½ 22

2 2 2 2 2 2 2

20 26 22 28 26 32 28 34 30 36 32 38

7 ½ 7 ½ 7 ½ 7 ½ 7 ½

103 ½

 Furnace opening should be ½ " larger than dimension EE for -8 thru -14; ¾ " larger than dimension EE for -16 thru -24.  Any tile length greater than GG x 1.2 should have a 30° angled flare from the standard tile extension.  Burner must be ordered with pilot, gas, and flame detector locations designated. See reverse side.  Backplate and pilot observation ports included with burner.

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSITON, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .