Dimensions & Installation 4482 Page 2
Arrangement Designators are specified relative to the main air connection at 12 o'clock and should be listed for pilot, gas, and flame detector in that order. Good practice dictates that neither the pilot nor the flame supervision device be on the bottom of the burner.
Burners are designed to be mounted no more than 15° from horizontal. Contact your North American Sales Engineer if your application requires a greater angle.
ATP BURNER TILE INSTALLATION RECOMMENDATIONS FOR HARD REFRACTORY LINED FURNACES
Furnace opening should be ½" larger than dimension EE for -8 thru -14; ¾" larger than dimension EE for -16 thru -24. Any tile length greater than GG × 1.2 should have a 30° angled flare from the standard tile extension. Two wraps of ½" soft fiberglass rope (Davlyn #100801 or equivalent) suitable for 1000 F service. North American can supply as part no. R540-0365. Specify length when ordering. Expansion joints must be provided in surrounding refractory to prevent pressure being exerted on cast or rammed burner tunnel section.