Sheet 4514-1 Page 2

Main Air Pressure, osi

4514-9 

0.25

1

4

8

16

Max. % XSAir  Max. % XSFuel

450 45 

600 45 

700

750

700

45

45

45

Flame Length/Diameter, inches on ratio, no XSAir

48/36

72/36

132/36

190/36

227/36

at max. XSAir at max. XSFuel

8/8

8/8

8/8

8/8

8/8

60/30

108/36

168/42

192/48

240/48

4514-10 

0.25

1

4

8

16

Max. % XSAir Max. % XSFuel

75

100 45 

150

250

350

45 

45

45

45

Flame Length/Diameter, inches on ratio, no XSAir

72/36 24/12 84/36

120/36

156/48

192/48

252/48

at max. XSAir at max. XSFuel

24/12

24/12

24/12

24/12

144/36

180/60

216/60

252/60

NOTES

  Maximum main air pressure at which pilot will light main flame is 1 osi for listed conditions.   Flame tends to lick up at these conditions.   Pilot will light main flame at all listed conditions.   Maximum main air pressure at which pilot will light main flame is 8 osi for listed conditions.   Pilot will not light main flame at listed conditions. All test data was obtained in an open laboratory furnace with free air available. Because of differing operating conditions in the field and a host of other variables, use reasonable caution in applying this data to field situations. Air pressure on the pilot was 8 osi in all tests. The 4514 Burner will generate an adequate signal for flame supervision at all conditions listed except as noted.

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.